Setting Functions; Function Setting Switches - YASKAWA DX200 Instructions Manual

Options jarcr-xfb01b board
Hide thumbs Also See for DX200:
Table of Contents

Advertisement

165626-1CD
JARCR-XFB01B Board
for DeviceNet
3

Setting Functions

3.1
3
Setting Functions

3.1 Function Setting Switches

Function Setting Switches
This section explains switches to set functions of the XFB01B board.
Make the proper settings following the instructions. For more details of
setting, refer to Section 3.2 "Setting Switches" on page 3-2.
SW1: Sets the DeviceNet operation mode and transmission baud rate,
and the XFB01B board transmission mode, slave or master.
SW1-1 (S/T)
Always set to OFF (normal operation mode).
SW1-2 (S/M)
Switches the mode, slave or master, for the XFB01B board.
SW1-3 and 1-4 (DR0 and DR1)
Sets the baud rate.
The baud rate for communications can be selected among the
following three rates.
• 125 kbps
• 250 kbps
• 500 kbps
SW2 and SW3: Sets the local node address of DeviceNet.
The setting range of local node address is from 0 to 63.
SW4: Sets the station number for the XFB01B board on the DX200.
The setting range of station number is from 1 (ST#01) to D (ST#13).
Do not set the station numbers 0 (ST#00), E (ST#14) and F (ST#15).
SW5: Sets the number of transmission I/O points.
(Set value of SW5)  8 is the actual number of I/O points.
The SW5 setting range is from "1" (8 points) to "E" (112 points).
<Example>
When the SW5 is set to "E", the number of I/O points are as follows.
• Input: 112 points
• Output: 112 points