YASKAWA DX200 Instructions Manual page 26

Options jarcr-xfb01b board
Hide thumbs Also See for DX200:
Table of Contents

Advertisement

JARCR-XFB01B Board
for DeviceNet
5
Allocating I/O Signals
5.1 I/O Module Setting
6. Confirm the status of the mounted I/O module.
– Only mounted I/O module is displayed. Confirm that each station
(ST#) is the same as the I/O module's actual mounting status.
– The following information is shown for each station.
ST#
Station address of I/O module
DI
Number of digital input points
DO
Number of digital output points
AI
Number of analog input points
AO
Number of analog output points
BOARD
Circuit board type
1 A hyphen "-" indicates the corresponding I/O module is not
mounted.
2 If the system cannot recognize the circuit board type, "*****" is
shown. There is no problem as long as the values displayed in
DI, DO, AI, and AO are correct.
– The followings are the configurations of boards as examples shown
in the above window in the Explanation 5.
ST#00: JANCD-YIO21-E board
This board is shown as YSF21 on the IO module display.
(digital input 40 points, digital output 40 points)
This board is fixed to ST#00.
ST#04: JARCR-XFB01B board
(digital input 16 points, digital output 16 points)
Switch SW4: Set to 4. (This value becomes the ST#.)
The following should be taken into consideration when
reading the display.
For the XFB01B board, as the number of I/O points
NOTE
reserved for the board status exists other than the number
of transmission I/O points set at SW5, the number of I/O
points shown in the display is the number calculated by "the
set value of SW5 + 1 (for the board status)".
5-3
1)
1)
1)
1)
2)
HW1481973
165626-1CD
26/70

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents