JARCR-XFB01B Board
for DeviceNet
6.1.2.2 Drop Line Length
6.1.2.3
Total Drop Line Length
6
Network Specifications
6.1 Network Configuration
The line connecting two nodes located farthest from each
other can use both thick and thin cables together. Compared
SUPPLE-
MENT
to the case of only a thick cable, the maximum network
length is short. In this case, the length of each cable needs
to fulfill the conditions in the following table.
Baud Rate (kbps)
500
250
125
L
: thick cable length, L
THICK
The drop line length is the line length between a branch point on the trunk
line to the farthest node that is located on the drop line.
The maximum drop line length is 6 m. A drop line can be branched out into
other drop lines.
The total drop line length is a total of all drop line lengths.
The total drop line length must be within the allowable range and even
then, each drop line must be 6 m or less.
The allowable range of total drop line length varies with the baud rate as
shown in the following table.
Baud Rate (kbps)
Total Drop Line Length (m)
500
39 max.
250
78 max.
125
156 max.
6-5
Maximum Network Length (m)
 100
L
+ L
THICK
THIN
+ 2.5 L
 250
L
THICK
THIN
+ 5.0 L
 500
L
THICK
THIN
: thin cable length