YASKAWA DX200 Instructions Manual page 17

Options jarcr-xfb01b board
Hide thumbs Also See for DX200:
Table of Contents

Advertisement

165626-1CD
JARCR-XFB01B Board
for DeviceNet
Switches
SW4
Station setting
SW5
Number of transmission I/O
points setting
3
Setting Functions
3.2 Setting Switches
Setting Method
Sets the station number.
The following shows the relations between the switch setting and the
station number.
Turn the arrow to the number corresponding to the desired station.
(Use a precision flat tip screwdriver.)
0:
Unavailable
1:
ST#01
2:
ST#02
3:
ST#03
4:
ST#04 (Default setting)
5:
ST#05
6:
ST#06
7:
ST#07
The number after ST# is the station number displayed on the programming
pendant of the DX200 when setting I/O modules.
Sets the number of I/O points to be transferred.
The following shows the relations between the switch setting and the
number of I/O points.
Turn the arrow to the number corresponding to the desired number of
I/O points.
(Use a precision flat tip screwdriver.)
0:
Unavailable
1:
8 [16]
2:
16 [24]
3:
24 [32]
4:
32 [40]
5:
40 [48]
6:
48 [56]
7:
56 [64]
The value in [ ] indicates the number of I/O points reserved for the XFB01B board
inside the DX200. (This includes the area for board status).
When setting SW4 station, do not use "0", "E", or "F". Be
NOTE
sure to set only one board to the each station. Failure of this
instruction may result in improper recognition of I/O module.
3-3
8:
ST#08
9:
ST#09
A:
ST#10
B:
ST#11
C:
ST#12
D:
ST#13
E:
Unavailable
F:
Unavailable
8:
64 [72]
9:
72 [80]
A:
80 [88]
B:
88 [96]
C:
96 [104]
D:
104 [112]
E:
112 [120] (Default setting)
F:
Unavailable
HW1481973
17/70

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents