Design Collect
Ÿ
The 'Design Collect' function allows users to set up a collection
template to guide Inspectors where, and in which order, readings
should be taken. This image can be used as a collection guide in
ElcoMaster™ 2.0 or transferred to an Android mobile phone or
tablet using ElcoMaster™ for Android™, see page 46.
To use Design Collect, switch ElcoMaster™ 2.0 to Advanced Mode by clicking on the Expand Arrow and
selecting 'Start Advanced Mode'.
www.elcometer.com
Click on the Design Collect tab and
Ÿ
select an existing template or click
'New Design'
When creating a new design you will
be asked to:
- Enter a name and description
- Select the Batch Type; Profile,
Material Thickness, DFT or Surface
Cleanliness
- Add the required image to collect
readings against
- Specify the number of readings to be
collected
- Enter relevant Limits
- Request a prompt to begin the next set
of readings or begin automatically
- Choose to create a new batch for each
set of readings or create a single batch
with multiple reading sets
Click 'Finish' to begin the design
Ÿ
To design the 'collect' image sequence,
simply click and hold each 'reading'
circle in turn, drag onto the image where
readings are to be taken and adjust the
size accordingly.
Once complete click 'Save' and click the
'X' button in the top right to close the
design window
R
46