16. INSTALL WASTE TRAY as displayed.
Close the Control Panel. Push the upper-right corner of the lower front
cover and remove the front panel. Insert a Waste Tray into the recep-
tacle.
17. Squeeze the Meniscus Reservoir (bottle) and confirm pump noise.
18.From the Control Panel, INSERT FIRST SET OF CARTRIDGES is
displayed.
Insert the first set of VisiJet Spectrum C4 cartridges into the Cyan, Ma-
genta, Yellow and Clear pockets. Allow cartridges to drain into internal
reservoirs for approximately twenty (20) minutes.
NOTE: Although the printer needs three of each cartridge to be
loaded before printing can begin, this first set is enough fluid
for us to fill the heads and confirm proper operation. Do not add
remaining two cartridges until prompted to do so.
Press CONTINUE on LCD panel.