16
BRAKE SYSTEM
–
Move the brake fluid reservoir mounted on the handlebar to a horizontal position.
–
Cover the painted parts.
–
Remove screws
–
Remove cover
–
Draw the old brake fluid out of the brake fluid reservoir using a syringe and fill with
fresh brake fluid.
Bleed syringe (50329050000) (
Brake fluid DOT 4 / DOT 5.1 (
202683-10
–
Mount bleeder cover
Bleeder cover (00029013018) (
–
Connect the bleeding device.
Bleeding device (00029013100) (
202684-10
–
Open shut-off valve
Info
Follow the operating instructions of the bleeding device.
–
Ensure that the inflation pressure is correctly set at pressure gauge
sary, adjust the inflation pressure at pressure regulator
Guideline
Filling pressure
201494-10
–
Pull off protection cap
the bleeder bottle.
Bleeding device (00029013100) (
–
Open bleeder screw
Info
Bleed until fresh brake fluid emerges from the bleeder bottle hose without
bubbles.
202685-10
–
Tighten the bleeder screw.
–
Close shut-off valve
–
Open the bleeder screw again until brake fluid stops emerging.
Info
This prevents overfilling of the brake fluid reservoir.
–
Tighten the bleeder screw. Remove the hose of the bleeder bottle. Mount the pro-
tection cap.
–
Disconnect the bleeding device. Remove the bleeder cover.
–
Add brake fluid to level
Guideline
Level
C
tainer rim)
Brake fluid DOT 4 / DOT 5.1 (
–
Position the cover with the membrane. Mount and tighten the screws.
Info
201894-12
Clean up overflowed or spilt brake fluid immediately with water.
.
1
with membrane.
2
p. 206)
p. 202)
.
3
p. 206)
.
4
of the brake caliper bleeder screw. Connect the hose of
5
by approx. one half turn.
6
.
4
.
C
(brake fluid level below con-
p. 202)
p. 206)
.
B
2... 2.5 bar (29... 36 psi)
p. 206)
5 mm (0.2 in)
88
. If neces-
A