2
If the server does not power on, verify the following items:
•
The site power is available.
•
The power cord is properly connected to the server power jack and to a working power source.
•
The internal power supply cable is properly connected to the system board.
Health LED warning conditions
Health LED warning condition
Amber, blinking at 1 flash per second
Red, blinking at 1 flash per second
Red, blinking at 1 flash per 4 seconds
1
10°C to 35°C (50°F to 95°F)
Rear panel components
Item
Component
1
Padlock eye
2
Kensington security slot
Cause
Ambient temperature or server temperature is above
the operating temperature range.
See Fan and thermal issues.
•
A fan is not installed.
•
The fan has failed.
•
Ambient or server temperatures are above the
operating temperature range.
See Fan and thermal issues.
System power problems exist. See Hardware
issues.
Description
To lock the chassis cover and prevent access to the internal
components, attach a padlock here.
To secure the server to a heavy or immovable object, connect
an anti-theft security cable here.
1
1
Table Continued
Health LED warning conditions
11
Need help?
Do you have a question about the ProLiant MicroServer Gen10 Series and is the answer not in the manual?
Questions and answers