Error message
Error: Thermal temperature condition has been
degraded, the system may or may not shut down
depending on thermal shutdown setting.
Warning: System was probably shut down due to the
thermal temperature condition being set to degraded
at last boot.
Warning: System was shut down due to thermal
temperature condition being set to failed at last boot.
Warning: Power fault detected at last boot.
Description
Either the environmental temperature or the internal
system temperature has triggered a warning
condition.
If the Thermal Shutdown option is enabled in the
Aptio Setup Utility, the system will automatically
initiate a graceful shutdown to protect the system. To
check, access the Aptio Setup Utility. Then, select
Advanced > Hardware Health Configuration.
See Fan and thermal issues.
Either the environmental temperature or the internal
system temperature triggered a warning condition
when the system was last powered on.
If the Thermal Shutdown option was enabled and
the OS power button is set to shut down the system,
a graceful shutdown occurred to protect the system.
See Fan and thermal issues.
Either the environmental temperature or the internal
system temperature triggered a failed condition when
the system was last powered on. The system shuts
down immediately for protection.
See Fan and thermal issues.
A power fault event was detected during the last
boot.
See Power issues.
Hardware issues
49
Need help?
Do you have a question about the ProLiant MicroServer Gen10 Series and is the answer not in the manual?