Figure 23
Touch screen
13 Disconnect a cable from the back of the breakaway board (see Figure 24).
Figure 24
14 To remove the Autoprobe board, remove the two T10 screws and then slide the board to the right to
disengage the two latches on either side of the board (see Figure 25). When reattaching the Autoprobe
board, do not fully tighten the two T10 screws until you have reattached the front panel keyboard
to the oscilloscope and attached it to the Autoprobe board. You will need some room to work with
and if you fully tighten the screws on the Autoprobe board, you will have none. Once the front
panel keyboard is attached, tighten the Autoprobe screws to 5 in-lbs.
Chapter 5: Replacing Assemblies
front panel bezel, front panel keyboard, touch screen, and Autoprobe board
These are two of the latches you are disengaging
when you pull the board straight away from the
touch screen
To remove and replace the
Push breakaway board
straight out away from
the touch screen and
then lift up
This is the edge that
breaks away from the
front panel keyboard
(they come attached
together)
Disconnect
this cable
93