Connecting Power to the Chassis
Step
5
6
7
3-24
Action
Insert the stripped end of the wire into the compression terminal. Be sure to
insert the wire between the retainer and the back of the connector.
To facility ground
If the screw comes in direct contact with the wire, remove the wire and
insert it below the retainer to ensure a proper ground connection.
Use the 1/4-inch flat-tip screwdriver to tighten the locking screw to 24 in-lb.
Ensure that the other end of the ground cable is properly connected for
frame grounding.
Turn clockwise
to tighten screw
to 24 in-lb.
1/4-inch flat-tip
screwdriver
CVX-0233A