operation executing will be cancelled by pressing key <Esc>
during waiting for insert/remove a device to/from ZIF.
This feature is available for JetProg, BeeProg and LabProg+
programmer only.
Note: During waiting for an insertion a new device into ZIF
socket, the LED BUSY on the programmer is blinking.
This mode may be enabled or disabled by item Automatic
YES! mode. If a new programmer is selected Options / Find
programmer, this mode will be disabled.
In Response time is possible to set a time interval within must
be detected device in ZIF socket to accept an insertion of a
new device. Default is set standard interval. If socket adapter
is used then is recommended to set an elongated interval.
In Pins with capacitors bar may be entered a list of a pins
interconnected by capacitors (for example: if a converter,
which have connected capacitor between VCC and GND, is
used), which may makes problems at detecting insertion of a
new device.
List of pins of device is in form:
pinA, pinB, pinC....
Example: 4,6,17
This list is erased if a new device is selected by Device /
Select default or Device / Select device ...
This setting is saved to disk by command Options / Save
options.
Options / Log file
This options associates with using of Log window. All reports
for this window can be written into the Log file too. The Log
file name as REPORT.REP and the control program creates
this file in current directory.
Sets New caused deleting old Log file if exist and creating a
new file for reports. Sets Append adds all reports into existing
Log file. If file not exist, the new file will be created. Settings
are applied only at program start.
This setting can be saved to disk by command Options / Save
options. Default form is set to a using Log window without Log
file i.e. all reports will be displayed to a Log window only.
Options / Protected mode
Protected mode is special mode of program. When program is
in Protected mode, there are disabled program operation and
commands that can modify buffer or device settings. Protected