5.18.4 mode
Description Set downstream/upstream rate adaptive mode to init (rate
Syntax
Parameter
5.18.5 noise
Description Set downstream/upstream minimum impulse noise protection.
Syntax
Parameter
5.18.6 noisemargin
Description Set Downshift/Upshift Noise Margin in downstream/upstream
Syntax
Parameter
automatically selected at start up only and does not change after that),
dynamic (rate automatically selected at initialization and is
continuously adapted during show time), or manual (rate changed
manually)
mode {ds | us} {init | dynamic | manual}
None
noise {ds | us} <number>
Name
Description
number
Noise (tenth symbols).
Valid values: 0~8 step 0.1
Default value: -
Type: Mandatory
direction
noisemargin {ds | us} {downshift | upshift} <number>
Name
Description
number
Downshift/Upshift Noise Margin (tenth
symbols).
Valid values: 0~31 step 0.1
Default value: -
Type: Mandatory
- 353 -