B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 33 of 46)
ADDR
REGISTER NAME
B0F4
IEC 61850 MMXU PF.phsC Deadband 1
B0F6
...Repeated for Deadband 2
B12C
...Repeated for Deadband 3
B162
...Repeated for Deadband 4
B198
...Repeated for Deadband 5
B
B1CE
...Repeated for Deadband 6
IEC 61850 GGIO2 Control Configuration (Read/Write Setting) (64 modules)
B240
IEC 61850 GGIO2.CF.SPCSO1.ctlModel Value
B241
IEC 61850 GGIO2.CF.SPCSO2.ctlModel Value
B242
IEC 61850 GGIO2.CF.SPCSO3.ctlModel Value
B243
IEC 61850 GGIO2.CF.SPCSO4.ctlModel Value
B244
IEC 61850 GGIO2.CF.SPCSO5.ctlModel Value
B245
IEC 61850 GGIO2.CF.SPCSO6.ctlModel Value
B246
IEC 61850 GGIO2.CF.SPCSO7.ctlModel Value
B247
IEC 61850 GGIO2.CF.SPCSO8.ctlModel Value
B248
IEC 61850 GGIO2.CF.SPCSO9.ctlModel Value
B249
IEC 61850 GGIO2.CF.SPCSO10.ctlModel Value
B24A
IEC 61850 GGIO2.CF.SPCSO11.ctlModel Value
B24B
IEC 61850 GGIO2.CF.SPCSO12.ctlModel Value
B24C
IEC 61850 GGIO2.CF.SPCSO13.ctlModel Value
B24D
IEC 61850 GGIO2.CF.SPCSO14.ctlModel Value
B24E
IEC 61850 GGIO2.CF.SPCSO15.ctlModel Value
B24F
IEC 61850 GGIO2.CF.SPCSO16.ctlModel Value
B250
IEC 61850 GGIO2.CF.SPCSO17.ctlModel Value
B251
IEC 61850 GGIO2.CF.SPCSO18.ctlModel Value
B252
IEC 61850 GGIO2.CF.SPCSO19.ctlModel Value
B253
IEC 61850 GGIO2.CF.SPCSO20.ctlModel Value
B254
IEC 61850 GGIO2.CF.SPCSO21.ctlModel Value
B255
IEC 61850 GGIO2.CF.SPCSO22.ctlModel Value
B256
IEC 61850 GGIO2.CF.SPCSO23.ctlModel Value
B257
IEC 61850 GGIO2.CF.SPCSO24.ctlModel Value
B258
IEC 61850 GGIO2.CF.SPCSO25.ctlModel Value
B259
IEC 61850 GGIO2.CF.SPCSO26.ctlModel Value
B25A
IEC 61850 GGIO2.CF.SPCSO27.ctlModel Value
B25B
IEC 61850 GGIO2.CF.SPCSO28.ctlModel Value
B25C
IEC 61850 GGIO2.CF.SPCSO29.ctlModel Value
B25D
IEC 61850 GGIO2.CF.SPCSO30.ctlModel Value
B25E
IEC 61850 GGIO2.CF.SPCSO31.ctlModel Value
B25F
IEC 61850 GGIO2.CF.SPCSO32.ctlModel Value
B260
IEC 61850 GGIO2.CF.SPCSO33.ctlModel Value
B261
IEC 61850 GGIO2.CF.SPCSO34.ctlModel Value
B262
IEC 61850 GGIO2.CF.SPCSO35.ctlModel Value
B263
IEC 61850 GGIO2.CF.SPCSO36.ctlModel Value
B264
IEC 61850 GGIO2.CF.SPCSO37.ctlModel Value
B265
IEC 61850 GGIO2.CF.SPCSO38.ctlModel Value
B266
IEC 61850 GGIO2.CF.SPCSO39.ctlModel Value
B267
IEC 61850 GGIO2.CF.SPCSO40.ctlModel Value
B268
IEC 61850 GGIO2.CF.SPCSO41.ctlModel Value
B269
IEC 61850 GGIO2.CF.SPCSO42.ctlModel Value
B26A
IEC 61850 GGIO2.CF.SPCSO43.ctlModel Value
B26B
IEC 61850 GGIO2.CF.SPCSO44.ctlModel Value
B26C
IEC 61850 GGIO2.CF.SPCSO45.ctlModel Value
B26D
IEC 61850 GGIO2.CF.SPCSO46.ctlModel Value
B26E
IEC 61850 GGIO2.CF.SPCSO47.ctlModel Value
B-40
RANGE
UNITS
0.001 to 100
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
D30 Line Distance Relay
APPENDIX B
STEP
FORMAT
%
0.001
F003
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
DEFAULT
10000
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents