GE D30 Instruction Manual page 387

Line distance
Hide thumbs Also See for D30:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 26 of 46)
ADDR
REGISTER NAME
8B54
...Repeated for Digital Element 18
8B68
...Repeated for Digital Element 19
8B7C
...Repeated for Digital Element 20
8B90
...Repeated for Digital Element 21
8BA4
...Repeated for Digital Element 22
8BB8
...Repeated for Digital Element 23
8BCC
...Repeated for Digital Element 24
8BE0
...Repeated for Digital Element 25
8BF4
...Repeated for Digital Element 26
8C08
...Repeated for Digital Element 27
8C1C
...Repeated for Digital Element 28
8C30
...Repeated for Digital Element 29
8C44
...Repeated for Digital Element 30
8C58
...Repeated for Digital Element 31
8C6C
...Repeated for Digital Element 32
8C80
...Repeated for Digital Element 33
8C94
...Repeated for Digital Element 34
8CA8
...Repeated for Digital Element 35
8CBC
...Repeated for Digital Element 36
8CD0
...Repeated for Digital Element 37
8CE4
...Repeated for Digital Element 38
8CF8
...Repeated for Digital Element 39
8D0C
...Repeated for Digital Element 40
8D20
...Repeated for Digital Element 41
8D34
...Repeated for Digital Element 42
8D48
...Repeated for Digital Element 43
8D5C
...Repeated for Digital Element 44
8D70
...Repeated for Digital Element 45
8D84
...Repeated for Digital Element 46
8D98
...Repeated for Digital Element 47
8DAC
...Repeated for Digital Element 48
FlexElement (Read/Write Setting) (16 modules)
9000
FlexElement™ 1 Function
9001
FlexElement™ 1 Name
9004
FlexElement™ 1 InputP
9005
FlexElement™ 1 InputM
9006
FlexElement™ 1 Compare
9007
FlexElement™ 1 Input
9008
FlexElement™ 1 Direction
9009
FlexElement™ 1 Hysteresis
900A
FlexElement™ 1 Pickup
900C
FlexElement™ 1 DeltaT Units
900D
FlexElement™ 1 DeltaT
900F
FlexElement™ 1 Pickup Delay
9010
FlexElement™ 1 Reset Delay
9011
FlexElement™ 1 Block
9012
FlexElement™ 1 Target
9013
FlexElement™ 1 Events
9014
...Repeated for FlexElement™ 2
9028
...Repeated for FlexElement™ 3
903C
...Repeated for FlexElement™ 4
9050
...Repeated for FlexElement™ 5
9064
...Repeated for FlexElement™ 6
9078
...Repeated for FlexElement™ 7
GE Multilin
RANGE
0 to 1
---
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0.1 to 50
-90 to 90
0 to 2
20 to 86400
0 to 65.535
0 to 65.535
0 to 65535
0 to 2
0 to 1
D30 Line Distance Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
---
F206
---
1
F600
---
1
F600
---
1
F516
---
1
F515
---
1
F517
%
0.1
F001
pu
0.001
F004
---
1
F518
---
1
F003
s
0.001
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
DEFAULT
B
0 (Disabled)
"FxE 1"
0
0
0 (LEVEL)
0 (SIGNED)
0 (OVER)
30
1000
0 (Milliseconds)
20
0
0
0
0 (Self-reset)
0 (Disabled)
B-33

Advertisement

Table of Contents
loading

Table of Contents