GE D30 Instruction Manual page 389

Line distance
Hide thumbs Also See for D30:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 28 of 46)
ADDR
REGISTER NAME
Direct Input/Output Names (Read/Write Setting) (96 modules)
9400
Direct Input 1 Name
9406
Direct Output 1 Name
940C
...Repeated for Direct Input/Output 2
9418
...Repeated for Direct Input/Output 3
9424
...Repeated for Direct Input/Output 4
9430
...Repeated for Direct Input/Output 5
943C
...Repeated for Direct Input/Output 6
9448
...Repeated for Direct Input/Output 7
9454
...Repeated for Direct Input/Output 8
9460
...Repeated for Direct Input/Output 9
946C
...Repeated for Direct Input/Output 10
9478
...Repeated for Direct Input/Output 11
9484
...Repeated for Direct Input/Output 12
9490
...Repeated for Direct Input/Output 13
949C
...Repeated for Direct Input/Output 14
94A8
...Repeated for Direct Input/Output 15
94B4
...Repeated for Direct Input/Output 16
94C0
...Repeated for Direct Input/Output 17
94CC
...Repeated for Direct Input/Output 18
94D8
...Repeated for Direct Input/Output 19
94E4
...Repeated for Direct Input/Output 20
94F0
...Repeated for Direct Input/Output 21
94FC
...Repeated for Direct Input/Output 22
9508
...Repeated for Direct Input/Output 23
9514
...Repeated for Direct Input/Output 24
9520
...Repeated for Direct Input/Output 25
952C
...Repeated for Direct Input/Output 26
9538
...Repeated for Direct Input/Output 27
9544
...Repeated for Direct Input/Output 28
9550
...Repeated for Direct Input/Output 29
955C
...Repeated for Direct Input/Output 30
9568
...Repeated for Direct Input/Output 31
9574
...Repeated for Direct Input/Output 32
FlexElement Actuals (Read Only) (16 modules)
9A01
FlexElement™ 1 Actual
9A03
FlexElement™ 2 Actual
9A05
FlexElement™ 3 Actual
9A07
FlexElement™ 4 Actual
9A09
FlexElement™ 5 Actual
9A0B
FlexElement™ 6 Actual
9A0D
FlexElement™ 7 Actual
9A0F
FlexElement™ 8 Actual
Teleprotection Inputs/Outputs (Read/Write Settings)
9B00
Teleprotection Function
9B01
Teleprotection Number of Terminals
9B02
Teleprotection Number of Channels
9B03
Teleprotection Local Relay ID
9B04
Teleprotection Terminal 1 ID
9B05
Teleprotection Terminal 2 ID
9B06
Reserved (10 items)
9B10
Teleprotection Input 1-n Default States (16 items)
9B30
Teleprotection Input 2-n Default States (16 items)
9B50
Teleprotection Output 1-n Operand (16 items)
GE Multilin
RANGE
0 to 96
1 to 96
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
0 to 1
2 to 3
1 to 2
0 to 255
0 to 255
0 to 255
0 to 1
0 to 3
0 to 3
0 to 65535
D30 Line Distance Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F205
---
1
F205
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
1
F102
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
---
F001
---
1
F086
---
1
F086
---
1
F300
DEFAULT
"Dir Ip 1"
"Dir Out 1"
B
0
0
0
0
0
0
0
0
0 (Disabled)
2
1
0
0
0
0
0 (Off)
0 (Off)
0
B-35

Advertisement

Table of Contents
loading

Table of Contents