GE D30 Instruction Manual page 122

Line distance
Hide thumbs Also See for D30:
Table of Contents

Advertisement

5.2 PRODUCT SETUP
The measured value settings for each of the 32 analog values are shown below.
PATH: SETTINGS
PRODUCT...
GGIO4 ANALOG
MEASURED VALUE
5
These settings are configured as follows.
ANALOG IN 1(32) VALUE: This setting selects the FlexAnalog value to drive the instantaneous value of each GGIO4
analog status value (GGIO4.MX.AnIn1.instMag.f).
ANALOG IN 1(32) DB: This setting specifies the deadband for each analog value. Refer to IEC 61850-7-1 and 61850-
7-3 for details. The deadband is used to determine when to update the deadbanded magnitude from the instantaneous
magnitude. The deadband is a percentage of the difference between the maximum and minimum values.
ANALOG IN 1(32) MIN: This setting specifies the minimum value for each analog value. Refer to IEC 61850-7-1 and
61850-7-3 for details. This minimum value is used to determine the deadband. The deadband is used in the determina-
tion of the deadbanded magnitude from the instantaneous magnitude.
ANALOG IN 1(32) MAX: This setting defines the maximum value for each analog value. Refer to IEC 61850-7-1 and
61850-7-3 for details. This maximum value is used to determine the deadband. The deadband is used in the determi-
nation of the deadbanded magnitude from the instantaneous magnitude.
Note that the
ANALOG IN 1(32) MIN
point numbers. Because of the large range of these settings, not all values can be stored. Some values may be
NOTE
rounded to the closest possible floating point number.
The report control configuration settings are shown below:
PATH: SETTINGS
PRODUCT SETUP
REPORT 1
CONFIGURATION
Changes to the report configuration will not take effect until the D30 is restarted.
The breaker configuration settings are shown below. Changes to these values will not take effect until the UR is restarted:
PATH: SETTINGS
PRODUCT SETUP
XCBR
CONFIGURATION
5-24
COMMUNICATIONS
1
ANALOG IN
Off
ANALOG IN
MESSAGE
0.000
ANALOG IN
MESSAGE
0.000
ANALOG IN
MESSAGE
0.000
and
ANALOG IN 1(32) MAX
COMMUNICATIONS
REPORT 1
RptID:
REPORT 1
MESSAGE
OptFlds:
REPORT 1
MESSAGE
BufTm:
REPORT 1
MESSAGE
TrgOps:
REPORT 1
MESSAGE
IntgPd:
COMMUNICATIONS
XCBR1 ST.LOC OPERAND
Off
XCBR2 ST.LOC OPERAND
MESSAGE
Off
D30 Line Distance Relay
IEC 61850...
GGIO4...
GGIO4 ANALOG 1(32) MEASURED VALUE
Range: any FlexAnalog value
1 VALUE:
Range: 0.000 to 100.000 in steps of 0.001
1 DB:
Range: –1000000000.000 to 1000000000.000 in steps
1 MIN:
of 0.001
Range: –1000000000.000 to 1000000000.000 in steps
1 MAX:
of 0.001
settings are stored as IEEE 754 / IEC 60559 floating
IEC 61850...
REPORT...
Range: up to 66 alphanumeric characters
Range: 0 to 65535 in steps of 1
0
Range: 0 to 4294967295 in steps of 1
0
Range: 0 to 65535 in steps of 1
0
Range: 0 to 4294967295 in steps of 1
0
IEC 61850 PROTOCOL
Range: FlexLogic™ operand
Range: FlexLogic™ operand
5 SETTINGS
REPORT 1(6) CONFIGURATION
XCBR CONFIGURATION
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents