Section 4: Display And Operation; User Interface; Instrument Keypad - Emerson Rosemount 1057 Instruction Manual

Three-input intelligent
Hide thumbs Also See for Rosemount 1057:
Table of Contents

Advertisement

Instruction Manual
LIQ-MAN-1057

Section 4: Display and Operation

4.1

User Interface

The Model 1057 has a large display which shows three live
measurement readouts in large digits and up to six additional
process variables or diagnostic parameters concurrently. The
display is back-lit and the format can be customized to meet
user requirements. The intuitive menu system allows access
to Calibration, Hold (of current outputs), Programming, and
Display functions by pressing the MENU button. In addition, a
dedicated DIAGNOSTIC button is available to provide
access to useful operational information on installed sensor(s)
and any problematic conditions that might occur. The display
flashes Fault and/or Warning when these conditions occur.
Help screens are displayed for most fault and warning
conditions to guide the user in troubleshooting.During
calibration and programming, key presses cause different dis
plays to appear. The displays are self-explanatory and guide the
user step-by-step through the procedure.
4.2

Instrument Keypad

There are four function keys and four selection keys on the instrument keypad.
Function Keys
The MENU key is used to access menus for programming and calibrating the instrument. Four top-
level menu items appear when pressing the MENU key:
Pressing MENU always causes the main menu screen to appear. Pressing MENU followed by EXIT causes the
main display to appear.
Pressing the DIAG key displays active Faults and Warnings, and provides detailed instrument information and
sensor diagnostics including: faults, warnings, sensor 1, 2 and 3 information, current outputs live values,
model configuration string e.g. 1057PPC03AN, Instrument Software version, and AC frequency.
Pressing ENTER on Sensor 1 or Sensor 2 provides useful diagnostics and information (as applicable):
measurement, sensor type, raw signal value, cell constant, zero offset and temperature. Offset, selected
measurement range, cable resistance, temperature sensor resistance, signal board software version.
The ENTER key - Pressing ENTER stores numbers and settings and moves the display to the next screen.
The EXIT key - Pressing EXIT returns to the previous screen without storing changes.
Section 4: Display and Operation
Calibrate – Calibrate attached sensors and analog
outputs.
Hold – Suspend current outputs.
Program – Program outputs, measurement,
temperature, security and reset.
Display – Program display format, language, warnings,
and contrast.