Page 2
This guide provides basic guidelines for Rosemount Wireless Pressure Gauges. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, or intrinsically safe (I.S.) installations. Refer to the Rosemount Wireless Pressure Gauge Reference Manual for more instruction. The manual and this guide are also available electronically.
Page 5
Feburary 2021 Quick Start Guide Required equipment Anti-seize paste or PTFE tape (for NPT threaded connection) Standard tools, e.g. screwdriver, wrench, pliers AMS Wireless Configurator version 12.0 or later, or Field Communicator Quick Start Guide...
Page 6
What's in the box? Wireless Pressure Gauge Quick Start Guide The following options are also available and will ship with the Rosemount Wireless Pressure Gauge if ordered. Rosemount 306 Integral Manifold (Model B4 Bracket (Model code B4) code S5) Emerson.com/Rosemount...
Page 7
Feburary 2021 Quick Start Guide Rosemount 1199 Seal (Model code S1) Product Certification (Model Codes below) Q4: Calibration Cert QG: Calibration Cert and GOST Verification Cert QP: Calibration Cert and Tamper Evident Seal Normal Range Indication (Model code LK) Q8: Material Traceability cert per EN 102043.1 Q15: Cert of Compliance to NACE MR0175/ISO 15156 for wetted materials...
Optional: Power/device check The device is designed to be installation-ready. To check device battery prior to installation, perform the following: Procedure 1. Perform Turn on device. 2. Slide the ON/OFF switch to the OFF position until ready for use. Emerson.com/Rosemount...
Feburary 2021 Quick Start Guide Optional: Normal range indication option Procedure 1. Modify each of the stickers to desired size prior to proceeding to step Step The stickers are intended to be installed on the dial only and should not be applied on the inside or outside of the housing cover. 2.
The vent path is between the housing and sensor. CAUTION Keep the vent path free of any obstruction, including but not limited to paint, dust, and lubrication by mounting the device so the process can drain away. Emerson.com/Rosemount...
Page 11
Feburary 2021 Quick Start Guide Figure 5-3: Low Side Pressure Port A. Low side pressure port (atmospheric reference) Turn on device Check to ensure the device and battery are working properly. Procedure 1. Twist the cover counterclockwise to remove it. 2.
Page 12
3. Double click the device under the HART modem. Eliminate mounting effects Devices are factory-calibrated. Once installed, it is recommended to perform this step to eliminate potential error caused by mounting position or static pressure. Instructions for using a Field Communicator are listed below. Emerson.com/Rosemount...
Page 13
Feburary 2021 Quick Start Guide Note See the Rosemount Wireless Pressure Gauge Reference Manual for the following: • Using AMS Wireless Configurator • Sensor trim function on absolute gauge Procedure 1. Vent the device. 2. Connect the Field Communicator. ®...
2, 2, 1, 1, 1 Keys 2. Follow the commands to perform the procedure. Wireless connectivity If the device has not joined to the network after power up, verify the following: • Active Advertising has been enabled on the Smart Wireless Gateway Emerson.com/Rosemount...
Page 15
Feburary 2021 Quick Start Guide • Network ID and Join Key in the device match the Network ID and Join Key of the Gateway The Network ID and Join Key may be obtained from the Smart Wireless Gateway on the Setup > Network > Settings page on the web interface. Quick Start Guide...
All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country ™ requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.
Page 17
Feburary 2021 Quick Start Guide Ordinary Location Certification from CSA The product has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by CSA, a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).
Page 18
4.7 ㎊. This must be considered only when the WPG is integrated into a system where the process connection is not grounded. 3. Do not change the battery when an explosive atmosphere is present. 4. Only replace battery with Rosemount Part No. 00G45-9000-0001. Emerson.com/Rosemount...
Page 19
Feburary 2021 Quick Start Guide International I7 IECEx Intrinsic Safety Certificate: IECEx BAS 16.0012X Standards: IEC 60079-0: 2011, IEC 60079-11: 2011 Markings: Ex ia IIC T4 Ga, T4 (-40 °C ≤ T ≤ +70 °C) IP66/67 Special Conditions for Safe Use (X): 1.
Page 20
Special Condition for Safe Use (X): See certificate for special condition. Korea IF KTL Intrinsic Safety Certificate: 16-KA4BO-0540X Markings: Ex ia IIC T4 Ga, T4 (-40 °C ≤ T ≤ +70 °C) Special Condition for Safe Use (X): See certificate for special condition Emerson.com/Rosemount...