6.3
6.3
© Copyright 2016 ABB. All rights reserved.
Troubleshooting
Malfunctions during operation
Malfunctions during operation
Lubricating oil pressure too low
Possible causes
Engine
Oil filter heavily contaminated
Defective oil pump in lubricating
system
Manometer display wrong
Turbo-
Rotor axial clearance too large
charger
Reduction in speed
Possible causes
Turbo-
Heavy contamination in the tur-
charger
bine
Damaged rotor components or
bearing
Lines
Defects such as leaks in the ex-
haust gas pipes or charge air
ducts
Increase in speed
Possible causes
Turbo-
Heavily contaminated nozzle
charger
ring (with 4-stroke application)
Operation Manual / TPL85-B14/-B15/-B16
6
6.3
Elimination
Clean it
Check / replace it
Replace the manometer
Contact an ABB Turbocharging
Service Station
Elimination
Clean it
Contact ABB Turbocharging
Service Station
Repair them
Elimination
Contact an ABB Turbocharging
Service Station
Page 79