Malfunctions during operation

Malfunctions during operation
Lubricating oil pressure too low
Possible causes
Engine
Oil filter heavily contaminated
Defective oil pump in lubricating
system
Manometer display wrong
Turbo-
Rotor axial clearance too large
charger
Reduction in speed
Possible causes
Turbo-
Heavy contamination in the tur-
charger
bine
Damaged rotor components or
bearing
Lines
Defects such as leaks in the ex-
haust gas pipes or charge air
ducts
Increase in speed
Possible causes
Turbo-
Heavily contaminated nozzle
charger
ring (with 4-stroke application)
Operation Manual / TPL85-B14/-B15/-B16
6
6.3
Elimination
Clean it
Check / replace it
Replace the manometer
Contact an ABB Turbocharging
Service Station
Elimination
Clean it
Contact ABB Turbocharging
Service Station
Repair them
Elimination
Contact an ABB Turbocharging
Service Station