Punch out guide tube
Fitting complete cleaning
pipe
© Copyright 2016 ABB. All rights reserved.
Maintenance
Cleaning the filter silencer
Hammer guide tube (03) free from peen fixing using a bolt
(diameter = 16 mm) and withdraw it.
Replace damaged parts of the complete cleaning pipe with original parts
from ABB Turbo Systems.
Refit guide tube (03) and peen fix it after putting insert units (E) in
place.
Fit feed pipe (02) and screw onto injection pipe (01) using connector.