5.4.1
NOTICE
Operating the water pres-
sure vessel
© Copyright 2016 ABB. All rights reserved.
Maintenance
Cleaning the compressor during
operation
Wet cleaning using external water-pressure vessel (XC3)
Operating state prerequisites for compressor cleaning with XC3
In order to carry out a successful cleaning procedure which has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisite must be met:
Engine load 25 to 85 %
Start the cleaning cycle according to following description Wet clean-
ing procedure with XC3.
Compressor wet cleaning procedure with XC3
It is mandatory to fulfil the operating condition prerequisites before
cleaning compressors with XC3.
Remove the sealing plug (X).
Fill the vessel with the required volume of clean water (see the Table
of cleaning parameters).