9.3
9.3
CAUTION
NOTICE
9.4
9.4
CAUTION
NOTICE
© Copyright 2016 ABB. All rights reserved.
Short-term turbocharger shut-down

Shutting off inlets and outlets

Shutting off inlets and outlets
Shut off the lubricating oil supply to the turbocharger.
This applies only to engines with several turbochargers and common
air as well as exhaust gas receivers.
Shut off compressor casing outlet, gas inlet and gas outlet by fitting
cover plates.
In this respect, refer to the engine manufacturer's instructions.
Bypass the turbocharger
Shut off the lubricating oil supply to the turbocharger.
This applies to engines with one turbocharger only:
The connections are ready and pipes for the bypass are available.
Fit bypass around turbocharger.
In this respect, refer to the engine manufacturer's instructions.