Hantek 1008 User Manual

Hantek 1008 User Manual

Digital
Hide thumbs Also See for 1008:

Advertisement

Hantek 1008
DIGITAL OSCILLOSCOPE
MANUAL
Hantek1008

Advertisement

Table of Contents
loading

Summary of Contents for Hantek 1008

  • Page 1 Hantek 1008 DIGITAL OSCILLOSCOPE MANUAL Hantek1008...
  • Page 2 Hantek 1008 DIGITAL OSCILLOSCOPE USER’S MANUAL Hantek1008 (Version 1. 0.0)
  • Page 3: Table Of Contents

    Hantek1008 Content General Safety Summary ……..………………………….…...3 CHAPTER 1: Getting Started…...…………………………..4 System Requirement..………………………………..5 Install Software..…………………….…………..…6 Install Driver....………………………..………..11 General Features..……………………..………..16 General Check....…………………..……...…..17 Probe Compensation....………..…...……..17 Functional Check............19 Seft Calibration............21 Accessaries...............22 CHAPTER 2: Operating Basics……………………………...23 The User’s Interface………………………....24 The Vertical System…...……………………..30 The Horizontal System……………………..…..32 The Trigger System......……………..33 Input Connectors..……………….…………………..35 CHAPTER 3: Understanding Function..…………………..36...
  • Page 4: General Safety Summary

    Hantek 1008 DIGITAL OSCILLOSCOPE General Safety Summary Review the following safety precautions carefully before operating the device to avoid any personal injuries or damages to the device including any products connected to it. To avoid any potential hazards use the device as specified by this user’s guide only.
  • Page 5: Chapter 1 Getting Started

    Hantek1008 Chapter 1 Getting Started The oscilloscope is small, compact, portable oscillo-scopes! The oscilloscope is ideal for production test, research and design and all of the applications involving analog circuits test and troubleshooting, as well as education and training. In addition to the list of general features on the next page, this chapter describes how to do the following tasks: ■...
  • Page 6: System Requirement

    Hantek 1008 DIGITAL OSCILLOSCOPE System Requirement To run oscilloscope software, the needs of computer configuration are as follows: Minimum System Requirement Operating System Window NT/2000/XP/VISTA/Win7 Processor Upwards of 1.00G processor Memory 256M byte Disk Space 500M disk free space Screen Resolution 800 x 600 pixel Recommended Configuration...
  • Page 7: Install Software

    Hantek1008 Install Software Note: Do not connect the USB connection until the software installation is complete. 1. While in Windows, insert the installation CD into the CD-ROM drive. 2. The installation should start up automatically. Otherwise in Windows Explorer, switch to the CD-ROM drive and run Setup.exe.
  • Page 8 Hantek 1008 DIGITAL OSCILLOSCOPE 4. Choose a destination directory. Click 'Next' to continue.
  • Page 9 Hantek1008 5. Check the setup information. Click Next to start copying files.
  • Page 10 Hantek 1008 DIGITAL OSCILLOSCOPE 6. This Status dialog is displayed during files copying. 7. Updating Your System Configuration.
  • Page 11 Hantek1008 8. The installation is completed.
  • Page 12: Install Driver

    Hantek 1008 DIGITAL OSCILLOSCOPE Install Driver 1. Connect the A-Type Plug of USB cable to your PC’s USB port. 2. Connect the B-Type Plug of USB cable to the device's USB port. 3. New hardware is found.
  • Page 13 Hantek1008 4. New hardware search wizard starts.
  • Page 14 Hantek 1008 DIGITAL OSCILLOSCOPE 5. Select the specific location.
  • Page 15 Hantek1008 6. New hardware search wizard starts to search the driver.
  • Page 16 Hantek 1008 DIGITAL OSCILLOSCOPE 7. New hardware wizard installs “DRIVER ”. 8. The wizard has finished installation of “DRIVER”.
  • Page 17: General Features

    Hantek1008 General Feature Product features: ■ 8 channel ■ Maximum real-time sample rate 2.4MSa/s ■ Max m emory depth 4K points ■ Built-in fast fourier transform function(FFT) ■ 20 Automatic measurements; ■ Automatic cursor tracking measurements; ■ Waveform storage, record and replay dynamic waveforms; ■...
  • Page 18: General Check

    Hantek 1008 DIGITAL OSCILLOSCOPE General Check Please check the instrument as following steps after receiving the oscilloscope: Check the shipping container for damage: Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness. Ensure and the instrument has been checked mechanically and electrically.
  • Page 19 Hantek1008 Correct Compensated Over compensated...
  • Page 20: Function Check

    Hantek 1008 DIGITAL OSCILLOSCOPE Under Compensated ■ If necessary, use the supplied non-metallic tool to adjust the trimmer capacitor of the probe for the flattest square wave being displayed on the oscilloscope. ■ Repeat if necessary. WARNNING: To avoid electric shock while using the probe, be sure the perfection of the insulated cable, and do not touch the metallic portions of the probe head while it is con- nected with a voltage source.
  • Page 21 Hantek1008 ■ Input a signal to a channel of the oscilloscope The oscilloscope is equipped with eight channels. Please input signal in the following steps: 1. Set the attenuation switch on the probe as 10X and connect the probe on the osci- lloscope with CH1.
  • Page 22: Seft Calibration

    Hantek 1008 DIGITAL OSCILLOSCOPE 3. Attach the tip of probe and ground tab to the Connector of Probe compensator. Click the button. A square wave will be displayed in several seconds. (Approximately 1 kHz, 2V, peak- to- peak). 4. Inspect CH2-CH8 with the same method. Repeat step 2 and 3.
  • Page 23: Accessaries

    Hantek1008 Accessories All the accessories list below are standard accessories for the oscilloscope: ■ Four Test Cables ■ An Auto lgnition Probes ■ A USB Cable ■ A PC software of the oscilloscope...
  • Page 24: Chapter 2 Operating Basics

    Hantek 1008 DIGITAL OSCILLOSCOPE Chapter 2 Operating Basics ■ The User’s Interface ■ The Menu System ■ The Vertical System ■ The Horizontal System ■ The Trigger System ■ Input Connectors...
  • Page 25: The User's Interface

    Hantek1008 The User’s Interface Click the software icon on the desk after you finished the software installation and equip- ment connecting. Then a user interface will be showed as follows: In addition to displaying waveforms, the display area is filled with many details about the waveform and the oscilloscope control settings.
  • Page 26 Hantek 1008 DIGITAL OSCILLOSCOPE 4. It shows the main time base setting. The Horizontal Panel The user can change Time/DIV, format in the panel. 6. The Vertical Panel The user can turn on/off the CH1/.../CH8. Also the user can change the CH1/ .../CH8 volt/div, coupling and probe attenuation.
  • Page 27 Hantek1008 The Menu System The Main Menu 1. File: load or save data, setup 2. View: Change the user interface...
  • Page 28 Hantek 1008 DIGITAL OSCILLOSCOPE 3. Setup: Setup setting 4. Display: Change wave display type 5. Cursor: Set Cursor measure type 6. Measure: Set measurement parameters...
  • Page 29 Hantek1008 7.Acquire: Run, stop or other operation setting 8. Utility: Utility setting 9. Window: Window setting...
  • Page 30 Hantek 1008 DIGITAL OSCILLOSCOPE 10. Vehicle: Vehicle setting 11. Help: Turn on help file...
  • Page 31: The Vertical System

    Hantek1008 The Vertical System Click “Setup”->” Vertical” The following figure shows the vertical parameters setting in the vertical Setup window. 1. Select channel : User can select the channel by clicking the Combo Box.
  • Page 32 Hantek 1008 DIGITAL OSCILLOSCOPE 2. ON/OFF: Turn on or off the selected channel. 3. VOLTS/DIV: Set the selected channel voltage range. 4. Coupling: DC 5. Probe: Set the Select one according to the probe attenuation factor to ensure correct vertical scale reading...
  • Page 33: The Horizontal System

    Hantek1008 The Horizontal System Click ”Setup”->“Horizontal” The following figure shows the horizontal parameters settings in the Horizontal System window. 1. Time/DIV: lead the setting of the time base parameters 2. Format: lead the setting of the horizontal format parameters...
  • Page 34: The Trigger System

    Hantek 1008 DIGITAL OSCILLOSCOPE The Trigger System Click “Setup”-> “Trigger” The following figure shows the trigger system control. 1. Trigger Mode: Sets the trigger mode...
  • Page 35 Hantek1008 2. Trigger Sweep: Select the trigger sweep mode to AUTO, NORMAL or SINGLE 3. Tirgger Source : Select the trigger source to CH1-CH8. 4. Trigger Slope: Select the edge trigger slope to Positive or Negative slope...
  • Page 36: Input Connectors

    Hantek 1008 DIGITAL OSCILLOSCOPE Input Connector CH1/.../CH8: Input connectors for waveform display. CAL: Probe compensation output. Other Connector: USB Port: Connect the B-Type Plug of USB cable to this port. Power Supply : Built in waveform generator. GND.: A ground terminal- not installed in this version.
  • Page 37: Chapter 3: Understanding Function

    Hantek1008 Chapter 3 Understanding Oscilloscope Functions ■ Set Oscilloscope ■ Set Vertical System ■ Set Horizontal System ■ Set Trigger System ■ Save/Load ■ Utility Function ■ Measure Signal ■ Print...
  • Page 38 Hantek 1008 DIGITAL OSCILLOSCOPE Setup the Oscilloscope Save Setup The oscilloscope software saves the current setup before you close the oscilloscope software. The oscilloscope recalls this setup the next time you run the software. You can use the “Save Setup” menu to permanently save several different setups.
  • Page 39: Set Vertical System

    Hantek1008 Set Vertical System Set Channel Click “Vertical” in “Setup” Menu. The Channel Selection The Channel Control Panel in sidebar. The Vertical function: Turn ON/Off : Turn on/off the channel. Volt/DIV: Select the channel voltage/div. Coupling : DC Probe: Select the channel probe attenuation Invert: Turn on/off the invert function.
  • Page 40 Hantek 1008 DIGITAL OSCILLOSCOPE You can also change the selected channel voltage in sidebar. You can left click and drag the mouse on the knob to change the voltage. Probe Attenuation Setting Select the attenuation factor for the probe. To check the probe attenuation setting, toggle the probe menu to match the attenuation factor of the probe.
  • Page 41 Hantek1008 Invert The invert function turns the displayed waveform 180 degrees, with respect to the ground level. When the oscilloscope is triggered on the inverted signal, the trigger is also inverted. Click “Invert” in Vertical window The following picture shows the waveform before inversion:...
  • Page 42 Hantek 1008 DIGITAL OSCILLOSCOPE The following picture shows the waveform of inversion:...
  • Page 43 Hantek1008 Set Math Click “MATH” in Channel menu to set MATH channel. The MATH Setup window ON/OFF: Turn On/Off the MATH Channel. Source A/B: Set the source of the math channel. Operate: Set operation type of the math channel. Volt/DIV: Set the resolution of the math channel. Probe: Set the math channel probe attenuation.
  • Page 44 Hantek 1008 DIGITAL OSCILLOSCOPE Operate Four Types: A + B Add source A and source B A - B Subtract source B from source A A × B Multiply source A by source B Divided source A by source B Convert a time-domain signal into its frequency components (spectrum).
  • Page 45 Hantek1008 Set Reference Click “REF” in “Setup” menu to set REF channel. The Reference Channel Function: On/Off: Turn on/off the reference channel. Volt/DIV: Change the resolution of the reference channel. Load: Load the reference waveform from the “.rfc” file from your computer. Save: Save the current reference waveform to your computer as “.rfc”...
  • Page 46 Hantek 1008 DIGITAL OSCILLOSCOPE Click “Save ” to save the waveform to *.rfc file. Then a saved source window appears. The save file window will appear after you select the saved source. The Reference Waveform Display Window: Note: If you turn on the “Reference” channel, the load file window will appear.
  • Page 47: Set Horizontal System

    Hantek1008 Setup Horizontal System Change Time/DIV The “Time/DIV” Select the horizontal Time/DIV (scale factor) for the main time base or for the window time base. The Horizontal Panel Click the blue knob can change Time/DIV. If the waveform acquisition is stopped, Time/DIV control expands or compresses the waveform.
  • Page 48 Hantek 1008 DIGITAL OSCILLOSCOPE Change Horizontal Position Double click the channel button to set the trigger point to the horizontal center of the screen. Horizontal position changes the displayed waveform position, relative to the trigger point. The user can drag...
  • Page 49: Set Trigger System

    Hantek1008 Set Trigger System Set Edge Trigger The trigger determines when the oscilloscope starts to acquire data and display a wave- form. When a trigger is set up properly, it can convert unstable displays or blank screens into meaningful waveforms. If the oscilloscope wants to acquire a waveform, it collects enough data so that it can draw the waveform to the left of the trigger point.
  • Page 50 Hantek 1008 DIGITAL OSCILLOSCOPE CH1: Select CH1 as trigger signal CH2: Select CH2 as trigger signal CH3: Select CH3 as trigger signal CH4: Select CH4 as trigger signal : Select CH5 as trigger signal : Select CH6 as trigger signal...
  • Page 51: Save/Load

    Hantek1008 Save/Load Save Click “File” in main menu to save data, setup and image. 1. Save Data Save waveform data as one of type file under Save Data. 2. Save Setup Save the current oscilloscope setup to file. 3. Save Image Save the software display window in a .bmp or .jpg format file.
  • Page 52 Hantek 1008 DIGITAL OSCILLOSCOPE Load Click “File” in main menu to recall saved waveform and setup. 1. Load Data Load the waveform that had saved. 2. Load Setup Load the instrument that had saved.
  • Page 53: Utility Function

    Hantek1008 Utility/Function Click "Untility" in main menu. Calibration The self calibration routine lets you optimize the oscilloscope signal path for maximum measurement accuracy. You can run the routine at any time but you should always run the routine if the ambient temperature changes by 5 deg or more. For accurate calibra- tion, power on the oscilloscope and wait twenty minutes to ensure it is warmed up.
  • Page 54 Hantek 1008 DIGITAL OSCILLOSCOPE Factory Setup Click “Factory Setup” in “Utility” menu to load default setups. When you click the Factory Setup in Utility menu, the oscilloscope displays the CH1 -CH8 waveforms and removes all waveforms. The oscilloscope set up for normal operation when it is shipped from the factory and can be recalled at anytime by user.
  • Page 55 Hantek1008 Language Click “Language” in “Utility” menu. There are two languages in “ Language” menu. The default language is English.
  • Page 56: Measure Signal

    Hantek 1008 DIGITAL OSCILLOSCOPE Measure Signal Cursor Menu Click “Cursor” in main menu. This method allows you to take measurements by moving the cursors. 1. Source The user can set the source to CH1, CH2, CH3,CH4 , CH5, CH6,CH7 CH8 8 MATH.
  • Page 57 Hantek1008 1) Cross The Cross cursors appear as cross lines on the display and measure the vertical and horizontal parameters. The Cross cursor display window The Cross measure result displays on status bar. 2) Trace The Trace cursors appear as vertical lines on the display and measure the waveform amplitude at the point the waveform crosses the cursor.
  • Page 58 Hantek 1008 DIGITAL OSCILLOSCOPE The Trace cursor display window The Trace cursor measure result display on status bar. 3) Vertical The Vertical cursors appear as vertical lines on the display and measure the vertical parameters.
  • Page 59 Hantek1008 The Vertical cursor display window The Vertical cursor measure result display on status bar. 4) Horizontal The Horizontal cursors appear as horizontal lines on the display and measure the hori- zontal parameters.
  • Page 60 Hantek 1008 DIGITAL OSCILLOSCOPE The Horizontal cursor display window The Horizontal cursor measure result display on status bar. Measure Menu Click “Measure” in main menu. The oscilloscope provides 20 parametric auto measurements (12 voltage and 8 time measurements).
  • Page 61 Hantek1008 1. Source The user can use the “Source” menu to select a measure source. 2. Vertical Maximum: Voltage of the absolute maximum level, measured over the entire waveform. Minimum: Voltage of the absolute minimum level, measured over the entire waveform. Peak To Peak: Peak-to-peak = Max –...
  • Page 62 Hantek 1008 DIGITAL OSCILLOSCOPE RMS: The Root Mean Square voltage over the entire waveform. Amplitude: Amp = Base – Top, measured over the entire waveform. Mean: The arithmetic mean over the entire waveform. Cycle Mean: The arithmetic mean over the first cycle in the waveform.
  • Page 63 Hantek1008 +Pulse Width: Measured of the first positive pulse in the waveform. The time between the 50% amplitude points. -Pulse Width: Measured of the first negative pulse in the waveform. The time between the 50% amplitude points. 4. Clear Measure Clear all measure items on display screen.
  • Page 64: The Display System

    Hantek 1008 DIGITAL OSCILLOSCOPE The Display System Display Type Click “Type” in “Display” menu. The following figure shows the type parameters setting. If the Vectors type mode is selected, the waveform will be displayed as following figure.
  • Page 65 Hantek1008 If the Dots type mode is selected, the waveform will be displayed as following figure. Display Grid Click “Display” in main menu.
  • Page 66 Hantek 1008 DIGITAL OSCILLOSCOPE The grid shows:...
  • Page 67 Hantek1008 The grid not shows: Intensity Click “Display->Intensity” in main menu.
  • Page 68 Hantek 1008 DIGITAL OSCILLOSCOPE The following figure shows the intensity dialog, which shows the display parameters setting. You can change the grid and waveform color intensity in this dialog.
  • Page 69 Hantek1008 Grid Background Color Click Grid Banckground Color in Display. You can change the banckground color. Click the black box, , , and you can set the background color.
  • Page 70: Print

    Hantek 1008 DIGITAL OSCILLOSCOPE Print And Print Preview 1. Click “Print” in “File” menu to set the printer to print the current waveform. 2. Click the “PrintPreview” in “File” menu to get into the Preview window. In “PrintPreview ” window, use the “Zoom In” button and the “Zoom Out” button to change the size of the waveform graph.
  • Page 71 Hantek1008 The Print report...
  • Page 72: Chapter 4 Application Example

    Hantek 1008 DIGITAL OSCILLOSCOPE Chapter 4 Application Example ■ Simple Measurement ■ Capturing a Single-Shot Signal ■ The Application of the X-Y ■ Taking Cursor Measurement...
  • Page 73: Simple Measurement

    Hantek1008 Simple Measurement User can adjust the controls to meet your measurement to optimize the waveform display. To measure the frequency and “Vpp”, you can do these steps as follows: 1. Click the “Measure->Horizontal->Frequency” button, the frequency of the signal display on the bottom of the waveform interface.
  • Page 74: Capturing A Single Shot Signal

    Hantek 1008 DIGITAL OSCILLOSCOPE Capturing a Single-Shot Signal To capture a single event, it needs to gather some pre-test knowledge of the signal in order to set up the trigger level and slope correctly. For example, if the event is derived from 3.3V COMS logic, a trigger level of 1.2 or higher Volts should work on a rising edge.
  • Page 75: The Application Of The X-Y

    Hantek1008 The Application of the X-Y Operation X-Y Plot acts to analyze correlation of data of two channels. Lissajous diagram is displayed in the screen when you use X-Y Plot, which enables to compare frequencies, amplitudes and phases of counterpart waveform against the reference waveform. This makes it possible to compare and analyze frequency, amplitude and phase between input and output.
  • Page 76 Hantek 1008 DIGITAL OSCILLOSCOPE Signal in X-Y Format:...
  • Page 77 Hantek1008 Instruction of the Ellipse Method Sinθ = A/B or C/D, where θ = phase shift (in degrees) between the two signals. From the formula above: θ = ±arcsine (A/B) or ±arcsine (C/D) If the main axis of the ellipse is between I and III quadrant, θ must be in the range of (0~π/2) or (3π/2~2π).
  • Page 78: Taking Cursor Measurements

    Hantek 1008 DIGITAL OSCILLOSCOPE Taking Cursor Measurements Use cursors to make time and amplitude measurements on a waveform quickly. Measure the Peak Frequency or Time of the First Sine Waveform Do these steps: 1. Click “Cursor->Source ”, select CH1(select CH2-CH8 if you want measure CH2-CH8).
  • Page 79 Hantek1008 Read the details showing in the status bar. Measure the Amplitude of the First Waveform Peak of the Waveform Do these steps: 1. Click “Cursor->Source”, select CH1 (select CH2 if you want measure CH2). 2. Click “Cursor->Type”, select Horizontal. 3.
  • Page 80 Hantek 1008 DIGITAL OSCILLOSCOPE Read the details showing in the status bar. Trace the Amplitude of a fixed position on X-axis in a Waveform Do these steps: 1. Click “Cursor->Source”, select CH1 (select CH2 if you want trace CH2). 2. Click “Cursor->Type”, select Trace.
  • Page 81 Hantek1008 Read the details showing in the status bar. Note: Click “Cursor->Type”, select “Cross”, you can measure time and amplitude at the same time.
  • Page 82: Chapter 5 Appendix

    Hantek 1008 DIGITAL OSCILLOSCOPE Chapter 5 Appendix ■ Appendix A: Specifications ■ Appendix B: General Maintenance...
  • Page 83: Appendix A

    Hantek1008 Appendix A: Specifications Specifications Table: Acquisition Sample Mode Real-Time Sample Sample Rate 2.4MSa/s(Single channel) Input Input Coupling Input Impedance Resistance: 1M Ω Supported Voltage 1X, 10X, 100X, 1000X, 10000X, 20:1 Attenuation Factors 400Vpk(DC + AC peak) Input Protection Horizontal Scanning Speed Range(Sec/Div) 1ns/div ~ 20000s/div(1-2-5 sequences) Time Base Accuracy...
  • Page 84 Hantek 1008 DIGITAL OSCILLOSCOPE Trigger Trigger Source CH1, CH2, CH3, CH4, CH5, CH6, CH7 and CH8 Trigger Mode Auto, Normal and Signal Edge Trigger Type Trigger Sensitivity 0.02 div increments Trigger Level Accuracy ±4 division Measurement Amplitude difference between cursors( Δ...
  • Page 85: Appendix B

    Hantek1008 Appendix B: General Maintenance General Care Do not store or leave the oscilloscope where the device will be exposed to direct sunlight for long periods of time. Caution To avoid damages to the device or probes, do not expose them to spray, liquids or solvents.