Content General Safety Summary ................1 Chapter 1 Getting Start .................. 2 1.1 System Requirement ................... 3 1.2 Install Software ..................... 4 1.3 Install Driver ......................7 1.4 General Features ....................11 1.5 General Check ....................12 1.6 Probe Compensation ..................12 1.7 Function Check ....................
Page 3
Chapter 5 Instructions of Hantek6022BL ........... 54 5.1 The User’s Interface ................... 55 5.2 The Menu System ....................56 5.3 The Tool Bar ....................... 58 5.4 The Control Panel ....................59 5.5 The Status bar ....................59 5.6 The Output Window ................... 60 5.7 Input Connector: ....................
Hantek 6022BL General Safety Summary Review the following safety precautions carefully before operate the device to avoid any personal injuries or damages to the device and any products connected to it. To avoid potential hazards use the device as specified by this user’s guide only.
Hantek 6022BL Chapter 1 Getting Start The oscilloscope is small, lightweight, no external power required, portable oscilloscopes! The oscilloscopes is ideal for production test, research and design and all of the applications involving analog circuits test and troubleshooting, as well as education and training.
Hantek 6022BL 1.1 System Requirement To run the oscilloscope software, the needs of computer configuration are as follows: Minimum System Requirements Operating System Window XP/Vista/Win7/Win8 Processor Upwards of 1.00G processor Memory 128M byte Disk Space 500M disk free space Screen resolution...
Hantek 6022BL 1.2 Install Software Caution: You must install the software before using the oscilloscope. While in Windows, insert the installation CD into the CD-ROM drive. The installation should start up automatically. Otherwise in Windows Explorer, switch to the CD-ROM drive and run Setup.exe.
Page 8
Hantek 6022BL Choose a destination directory. Click 'Next' to continue. Check the setup information. Click Next to start copying of files. User’s Manual...
Page 9
Hantek 6022BL This Status dialog is displayed during copying of files. Updating Your System Configuration. The installation is complete. User’s Manual...
Hantek 6022BL 1.3 Install Driver Connect the A-Type Plug of USB cable to your PC’S USB port. Connect the B-Type Plug of USB cable to USB port. New hardware is found. New hardware search wizard starts. User’s Manual...
Page 11
Hantek 6022BL 5. New hardware search wizard starts to search the driver. 6. New hardware wizard installs “DRIVER”. User’s Manual...
Page 12
Hantek 6022BL 7. The wizard has finished installing for “DRIVER”. 8. New hardware is found. User’s Manual...
Page 13
Hantek 6022BL 9. Found new hardware Wizard. Select “Install the software automatically”. 10. New hardware wizard installs software and finish new hardware search wizard. User’s Manual...
Hantek 6022BL 11. Your new hardware is installed and ready to use. 1.4 General Features Maximum real-time sample rate: 48MSa/s Memory depth: 1Mbytle/channel Built-in Fast Fourier Transform function(FFT); 20 Automatic measurements; Automatic cursor tracking measurements; Waveform storage; User selectable fast offset calibration;...
Hantek 6022BL 1.5 General Check Please check the instrument as following steps after receiving an oscilloscope: Check the shipping container for damage: Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has been checked mechanically and electrically.
Hantek 6022BL Over compensated Under Compensated ■ If necessary, use a non-metallic tool to adjust the trimmer capacitor of the probe for the fattest square wave being displayed on the oscilloscope. ■ Repeat if necessary. WARNNING: To avoid electric shock while using the probe, be sure the perfection of the insulated cable, and do not touch the metallic portions of the probe head while it is connected with a voltage source.
Page 17
Hantek 6022BL Input a signal to a channel of the oscilloscope The oscilloscope is equipped with dual channels. Please input signal in the following steps: Set the attenuation switch on the probe as 10X and connect the probe on the oscilloscope with CH1.
Hantek 6022BL 1.8 Self Calibration The self calibration routine lets you optimize the oscilloscope signal path for maximum measurement accuracy. You can run the routine at any time but you should always run the routine if the ambient temperature changes by 5 or more.
Hantek 6022BL Chapter 2 Operating Basics The User’s Interface The Menu System The Vertical System The Horizontal System The Trigger System Input Connector User’s Manual...
Hantek 6022BL 2.1 The User’s Interface Click the software icon on the desk after you finished the software setting and equipment connecting. Then click icon to run Hantek6022BE mode. In addition to displaying waveforms, the display area is filled with many details about the waveform and the oscilloscope control settings.
Page 21
Hantek 6022BL volt/div, coupling and probe attenuation. The Trigger Panel In this panel, the user can change the trigger mode, sweep, source and slope. Displays the system time. Displays Sample Rate Displays the main time base setting. 10. Displays the CH2 information Readouts show the coupling of the channels.
Hantek 6022BL 2.2 The Menu System The Main Menu of Hantek6022BE: File: Load or Save data, setup View: Change the user interface Horizontal: Set the horizontal system Vertical: Set the vertical system User’s Manual...
Page 23
Hantek 6022BL Trigger: Set the trigger system Display: The waveform display setup Cursor: Cursor measure setup Utility: Utility setting Help: Turn on help file User’s Manual...
Hantek 6022BL 2.3 The Vertical System Click “Vertical” in main menu The following figure shows the vertical system menu. It shows the vertical parameters setting. CH1: Leads to the setting of the CH1 parameters CH2: Leads to the setting of the CH2 parameters Use the left mouse button to dragging the channel icon to set the vertical position offset precisely.
Hantek 6022BL 2.5 The Trigger System Click “Trigger” in main menu. Mode: Sets the trigger mode to Edge trigger Sweep: Selects the trigger sweep mode to AUTO, NORMAL or SINGLE Source: Selects the trigger source to CH1, CH2. Slope: Selects the edge trigger slope to Positive or Negative slope The user can drag the trigger icon to adjust the trigger level and the trigger level will be displayed on the top right corner.
Hantek 6022BL 2.6 Input Connectors Input Connectors: 1. Button: press the button down to run hantek6022BE software. 2. USB PORT: Connect the B-Type Plug of USB cable to this port. CH 1/CH 2: Input connectors for waveform display. GND.: a ground terminal CAL.: Probe compensation output.
Hantek 6022BL Chapter 3 Understanding Function Set Oscilloscope Set Vertical System Set Horizontal System Set Trigger System Measure Signal Utility Function The Display System Save/Load Print User’s Manual...
Hantek 6022BL 3.1 Set Oscilloscope Save Setup The oscilloscope software saves the current setup before you close the oscilloscope software. The oscilloscope recalls this setup the next time you run the software. You can use the “Save Setup” menu to permanently save up to several different setups.
Hantek 6022BL You can left click and drag the mouse on the green knob or the yellow knob to change the voltage. Probe Attenuation Setting Select the attenuation factor for the probe. To check the probe attenuation setting, toggle the probe menu to match the attenuation factor of the probe.
Page 30
Hantek 6022BL Turn off invert Turn on invert The following picture shows the waveform before inversion: The following picture shows the waveform of inversion: User’s Manual...
Page 31
Hantek 6022BL 3.2.1 Set Math Click in Toolbar. The MATH Menu: Turn On/Off: Turn On/Off the MATH Channel. Source A/B: Set the sources of the math channel. Operate: Set operates type of the math channel. The mathematic functions include addition, subtract, multiply and division for CH1 and CH2.
Page 32
Hantek 6022BL The Math Function Display: Fast Fourier Transform Function To use the FFT mode, you need to click in Toolbar to open the FFT setup window. The FFT setup window: You can select the Source channel, Window algorithm, FFT number, and FFT Zoom...
Page 33
Hantek 6022BL factor. It displays only one FFT spectrum at a time. Source: Selects the channel used as the FFT source Window: Selects the FFT window type Scale: Selects the vertical scale units Vert Scale: Selects the vertical scale HORI Scale:...
Hantek 6022BL The Reference Waveform Display Window: Note: If you turn on the “Reference” channel, the load file window will appear. 3.3 Set Horizontal System The following figure shows the Horizontal System window. It shows the horizontal parameters settings. Time/DIV: leads the setting of the time base parameters Format: leads the setting of the horizontal format parameters The time base ranges of the oscilloscope is listed as follows.
Hantek 6022BL In the “Format” menu of the “Horizontal” menu, select the display mode to Y-T, X-Y. 3.4 Set Trigger System Click “Trigger” in main menu. The trigger determines when the oscilloscope starts to acquire data and display a waveform. When a trigger is set up properly, it can convert unstable displays or blank screens into meaningful waveforms.
Hantek 6022BL Source: You can use the trigger source options to select the signal that the oscilloscope uses as a trigger. CH1: Select CH1 as trigger signal CH2: Select CH2 as trigger signal Slope: Set the slope to Rising (+) or Falling (-).
Page 37
Hantek 6022BL Cross The Cross cursors appear as cross lines on the display and measure the vertical and horizontal parameters. The Cross cursor display window: Vertical The Vertical cursors appear as vertical lines on the display and measure the vertical parameters.
Page 38
Hantek 6022BL Horizontal The Horizontal cursors appear as horizontal lines on the display and measure the horizontal parameters. The Horizontal cursor display window: 3.5.2 Measure Click “Measure” in main menu. The oscilloscope provides 20 parametric auto measurements (12 voltage and 8 time measurements).
Page 39
Hantek 6022BL Maximum: Voltage of the absolute maximum level, Measured over the entire waveform Minimum: Voltage of the absolute minimum level, Measured over the entire waveform Peak To Peak: Peak-to-peak = Max – Min, Measured over the entire waveform Top: Voltage of the statistical maximum level, Measured over the entire waveform...
Hantek 6022BL The Measure Display Window: Note: The results of the automatic measurements will be displayed on the bottom of the screen. Maximum 8 results could be displayed at the same time. When there is no room, the next new measurement result will make the previous results moving left, out of screen.
Hantek 6022BL Interpolation Language 3.6.1 Default Setup Click “Default Setup” in “Utility” menu to load default setups When you click the Default Setup in Utility menu, the oscilloscope displays the CH1 and CH2 waveforms and removes all other waveforms. The oscilloscope set up for normal operation when it is shipped from the factory and can be recalled at anytime by user.
Hantek 6022BL 3.7 The Display System Click “Display” in main menu. The following figure shows the display system menu. Displays parameters setting. Type Grid Intensity 3.7.1 Type Click “Type” in “Display” menu. If the Vectors type mode is selected, the waveform will be displayed as following figure.
Page 45
Hantek 6022BL If the Dots type mode is selected, the waveform will be displayed as following figure. 3.7.2 Grid Click “Display” in main menu. User’s Manual...
Page 46
Hantek 6022BL The grid shows: Without the grid show: User’s Manual...
Page 47
Hantek 6022BL 3.7.3 Intensity Click “Display->Intensity” in main menu The following figure shows the intensity dialog. It shows the display parameters setting. You can change the grid and waveform color intensity in this dialog. User’s Manual...
Hantek 6022BL 3.8 Save/Load Menu Click “File” in main menu to save waveform, setups and screen Save Data Save waveform data Save Setups Save the current oscilloscope setups to file Load Menu Click “File” in main menu to recall saved waveform, setup...
Hantek 6022BL 3.9 Print Click “Print” in File. 1. Click “Print” in “File” menu to set the printer to print the current waveform. 2. Click the “PrintPreview” in “File” menu to get into the Preview window. In “PrintPreview” window, use the button to change the size of the waveform graph.
Hantek 6022BL Chapter 4 Application Example Simple Measurement Capturing a Single-Shot Signal The Application of the X-Y Taking Cursor Measurement User’s Manual...
Hantek 6022BL 4.1 Simple Measurement To acquire and display a signal, please do the steps as follows: Connect signal to CH1 by using probe The oscilloscope set the vertical, horizontal, and triggers controls at the best status automatically. Also, you can adjust the controls to meet your measurement to optimize the waveform display.
Hantek 6022BL The results of measure display in Information output. 4.2 Capturing a Single-Shot Signal To capture a single event, it needs to gather some pre-test knowledge of the signal in order to set up the trigger level and slope correctly. For example, if the event is derived from 3.3V COMS logic, a trigger level of 1.2 or higher Volts should work on a rising edge.
Hantek 6022BL usually higher a little above the normal level. When the trigger conditions are met, data appears on the display representing the data points that the oscilloscope obtained with one acquisition. 4.3 The Application of the X-Y X-Y Plot acts to analyze correlation of data of two channels. Lissajous diagram is displayed in the screen when you use X-Y Plot, which enables to compare frequencies, amplitudes and phases of counterpart waveform against the reference waveform.
Page 54
Hantek 6022BL Sinθ = A/B or C/D, where θ = phase shift (in degrees) between the two signals. From the formula above: θ = ±arcsine (A/B) or ±arcsine (C/D) θ must be in the range of (0~π/2) or (3π/2~2π) if the main axis of the ellipse is between I and III quadrant, .
Hantek 6022BL 4.4 Taking Cursor Measurements Use cursors to make time and amplitude measurements on a waveform quickly. Measure the Peak Frequency or Time of the First Sine Waveform Do these steps: Click “Cursor->Source”, select CH1 (select CH2 if you want measure CH2).
Page 56
Hantek 6022BL Note: Click “Cursor->Type”, select “Cross”, you can measure time and amplitude at one time. User’s Manual...
Hantek 6022BL Chapter 5 Instructions of Hantek6022BL The User’s Interface The Menu System The Toolbar The Control Panel The Status Bar Input Output Window Measurement User’s Manual...
Click icon to run Hantek6022BL mode. In addition to displaying waveforms, the display area is filled with many details about the waveform and the logic analyzer control settings.
Export As BMP File: Export data to file as “BMP” Print…: Print the current waveform Print Preview: Preview the current waveform Print Setup: Setup print type Exit: Exit Hantek6022BL 2. View: Change the user interface Docking Window: show window or not User’s Manual...
Page 60
Hantek 6022BL Status Bar: show status bar or not Application Look: show style, blue, black, silver or aqua style. 3. Display: The waveform display setup Zoom in: Enlargement waveform view : User can do the same thing by scrolling the mouse wheel down.
Hantek 6022BL 5.3 The Tool Bar The following figure shows the tool bar Export As CSV File: Export data to file as “CSV” Export As TXT File: Export data to file as “TXT” Export As BMP File: Export data to file as “BMP”...
The following figure shows the Control Panel. It shows the control parameters settings. The following figure shows the Control Panel. It shows the control parameters settings. Hantek6022BL(1.0.1): Name and version information of the software. Sample length: the length of sample points.
Hantek 6022BL 5.6 The Output Window The following figure shows the Output Window. It shows the output window settings. Channel Name Time Scale Waveform User’s Manual...
Hantek 6022BL 5.7 Input Connector: Button: press the button down to run hantek6022BL software. Pins : connect peripheral equipment 5.8 The Measurement The following figure shows the Measurement Click the button of cursor, you can see the picture Time : the time of the two measurement line...
Hantek 6022BL Appendix B: General Maintenance General Care Do not store or leave the oscilloscope where the device will be exposed to direct sunlight for long periods of time. Caution To avoid damages to the device or probes, do not expose them to sprays, liquids or solvents.