Advertisement

Hantek 6000EU Digital Oscilloscope
USER'S MANUAL
Hantek 6000EU
V1.0.1
http://www.Hantek.com
USER'S MANUAL
1

Advertisement

Table of Contents
loading

Summary of Contents for Hantek 6000EU

  • Page 1 Hantek 6000EU Digital Oscilloscope USER’S MANUAL Hantek 6000EU V1.0.1 http://www.Hantek.com USER’S MANUAL...
  • Page 2: Table Of Contents

    Hantek 6000EU Digital Oscilloscope Content General Safety Summary ................4 Chapter 1 Getting Start .................. 5 1.1 System Requirement ......................6 1.2 Install Software And Driver ....................7 1.3 General Features ....................... 10 1.4 General Check ........................11 1.5 Function Check ........................13 1.6 Self Calibration ........................
  • Page 3 Hantek 6000EU Digital Oscilloscope 4.1 Simple Measurement ......................69 4.2 Capturing a Single-Shot Signal ................... 70 4.3 The Application of the X-Y Operation ................70 4.4 Taking Cursor Measurements .................... 72 Chapter 5 Appendix ..................75 Appendix A: Specifications ...................... 76 Appendix B: Accessories ......................
  • Page 4: General Safety Summary

    Hantek 6000EU Digital Oscilloscope General Safety Summary Review the following safety precautions carefully before operate the device to avoid any personal injuries or damages to the device and any products connected to it. To avoid potential hazards use the device as specified by this user’s guide only.
  • Page 5: Chapter 1 Getting Start

    Hantek 6000EU Digital Oscilloscope Chapter 1 Getting Start The oscilloscope is small, lightweight, 12V external power required, portable oscilloscopes! The oscilloscopes is ideal for production test, research and design and all of the applications involving analog circuits test and troubleshooting, as well as education and training.
  • Page 6: System Requirement

    Hantek 6000EU Digital Oscilloscope 1.1 System Requirement To run the oscilloscope software, the needs of computer configuration are as follows: Minimum System Requirements Operating System Window Vista/Win7/Win8/Win10 Processor Upwards of 1.00G processor Memory 2G byte Disk Space 500M disk free space...
  • Page 7: Install Software And Driver

    Hantek 6000EU Digital Oscilloscope 1.2 Install Software And Driver Caution: You must install the software before using the oscilloscope. While in Windows, insert the installation CD into the CD-ROM drive. The installation should start up automatically. Otherwise in Windows Explorer, switch to the CD-ROM drive and run Setup.exe.
  • Page 8 Hantek 6000EU Digital Oscilloscope This Status dialog is displayed during copying of files. The installation is complete. USER’S MANUAL...
  • Page 9 Hantek 6000EU Digital Oscilloscope After software Installation it can be start the Device Driver Installation. Click Next to start the Device Driver Installation. Complete the Device Driver Installation. USER’S MANUAL...
  • Page 10: General Features

    Hantek 6000EU Digital Oscilloscope 1.3 General Features Product Features: ■ Four Channels, Max Bandwidth: 250MHz/200MHz/100MHz/70MHz ■ Maximum real-time sample rate: 1GSa/s ■ Memory depth: 128M /CH ■ Automatic setup for ease of use (AUTOSET); ■ Built-in Fast Fourier Transform function(FFT);...
  • Page 11: General Check

    Hantek 6000EU Digital Oscilloscope ■ Add, Subtract and Multiply Mathematic Functions; ■ Selectable 20 MHz bandwidth limit; ■ Waveform average; ■ Adjustable waveform intensity, more effective waveform view; ■ User interface in several user-selectable languages; ■ Waveform capture rate to 60,000 wfm/s,400,000wfm/s(FastAcq mode) ■...
  • Page 12 Hantek 6000EU Digital Oscilloscope ■ From the “Probe” menu, select attenuation to 1:10. Set the switch to “X10” on the probe and connect it to CH1 of the oscilloscope. When using the probe hook-tip, insert the tip onto the probe firmly to ensure a proper connection.
  • Page 13: Function Check

    Hantek 6000EU Digital Oscilloscope 1.5 Function Check Perform this functional check to verify that your oscilloscope is operating correctly ■ Connect the oscilloscope You should connect the A-Type Plug of USB cable to your PC USB port and connect the other A-Type Plug of USB cable to oscilloscope USB port.
  • Page 14: Self Calibration

    Hantek 6000EU Digital Oscilloscope 3. Attach the tip of probe and ground nip to the Connector of Probe compensator. Click the button. A square wave will be displayed within a several seconds. (Approximately 1 kHz, 2V, peak- to- peak). 4. Inspect CH2 with the same method. Repeat steps 2 and 3.
  • Page 15: Accessories

    Hantek 6000EU Digital Oscilloscope 1.7 Accessories All the accessories listed below are standard accessories for the oscilloscope: Hantek 6000EU:  Probe x 2 (1.5m), 1:1(10:1), Passive Probes  A USB cable Alligator clip wire x 2  QuickGuide  A software installation CD...
  • Page 16: Chapter 2 Operating Basics

    Hantek 6000EU Digital Oscilloscope Chapter 2 Operating Basics The User’s Interface The Menu System The Vertical System The Horizontal System The Trigger System Input Connectors USER’S MANUAL...
  • Page 17: The User's Interface

    Hantek 6000EU Digital Oscilloscope 2.1 The User’s Interface Click the software icon on the desk after you finished the software setting and equipment connecting. Then a user interface will be showed as follows: In addition to displaying waveforms, the display area is filled with many details about the waveform and the oscilloscope control settings.
  • Page 18 Hantek 6000EU Digital Oscilloscope 9. Move Wareform 10. Displays the system time. 11. Sample rate 12. The markers show the CH1/CH2/CH3/CH4 reference points of the displayed waveforms. If there is no marker,the channel is not displayed. 13. Connect 14. Displays the CH1/CH2/CH3/CH4 information: Readouts show the coupling of the channels.
  • Page 19: The Menu System

    Hantek 6000EU Digital Oscilloscope 2.2 The Menu System The Main Menu: 1.File: Load or Save data, setup 2.View: Change the user interface 3.Setup: Setup setting 4.Display: Change wave display type USER’S MANUAL...
  • Page 20 Hantek 6000EU Digital Oscilloscope 5.Cursor: Set Cursor measure type 6. Measure: Set measurement parameters 7.Acquire: Run ,Stop or other operation setting 8. Utility: Utility setting 9. Window: Window setting USER’S MANUAL...
  • Page 21: The Vertical System

    Hantek 6000EU Digital Oscilloscope 10.Help: Turn on help file 2.3 The Vertical System Click “Setup->Vertical” The following figure shows the vertical Setup window. It shows the vertical parameters setting. 1.Select channel: User can select the channel by clicking the Combo box.
  • Page 22: The Horizontal System

    Hantek 6000EU Digital Oscilloscope 3.VOLTS/DIV: Set the selected channel voltage range. 4.Coupling: Set the selected channel to DC/AC. 5.Probe: Set the Select one according to the probe attenuation factor to ensure correct vertical scale reading 6.BW Limit: Reject the frequency component higher than 20MHz.
  • Page 23: The Trigger System

    Hantek 6000EU Digital Oscilloscope 1. Time/DIV: leads the setting of the time base parameters 2. Format: leads the setting of the horizontal format parameters 2.5 The Trigger System Click “Setup-> Trigger” The following figure shows the trigger system control. USER’S MANUAL...
  • Page 24: Input Connector

    Hantek 6000EU Digital Oscilloscope Trigger: 1.Trigger Mode: Sets the trigger mode 2.Trigger Sweep: Selects the trigger sweep mode to AUTO, NORMAL or SINGLE 3.Trigger Source: Selects the trigger source to CH1, CH2, CH3, CH4 4.Trigger Slope: Selects the edge trigger slope to Positive or Negative slope 2.6 Input Connector...
  • Page 25 Hantek 6000EU Digital Oscilloscope USB PORT: Connect the USB cable to this port. CAL.: Probe compensation output. ■ SATA Interface communication The SATA interface is the communication interface that connects the instrument combination. The SATA data interface is defined as follows:...
  • Page 26: Chapter 3 Oscilloscope Functions

    Hantek 6000EU Digital Oscilloscope Chapter 3 Oscilloscope Functions Set Oscilloscope Set Vertical System Set Horizontal System Set Trigger System Save/Load Utility Function Measure Signal Zoom In/Out Waveforms Acquire Signal Print USER’S MANUAL...
  • Page 27: Setup The Oscilloscope

    Hantek 6000EU Digital Oscilloscope 3.1 Setup the Oscilloscope Using “AUTOSET” to display a signal automatically. Auto setup functions one time each time you push the “AUTOSET” button. The function obtains a stable waveform display for you. It automatically adjusts the vertical scale, horizontal scale and trigger settings.
  • Page 28: Set Vertical System

    Hantek 6000EU Digital Oscilloscope 3.2 Set Vertical System Set Channel Click “Vertical” in “Setup” menu. The Channel Selection The Channel Control Panel in sidebar The Vertical function: Turn ON/Off: Turn on/off the channel Volt/DIV: Select the channel voltage/div Coupling: Select the channel coupling Probe: Select the channel probe attenuation Invert: Turn on/off the invert function.
  • Page 29 Hantek 6000EU Digital Oscilloscope Set Channel Coupling Click “Coupling” in “Vertical Setup” window In the sidebar, you can change the channel coupling too You can set the coupling to DC, AC or GND. If you set the coupling to DC, it blocks the AC component of the input signal.
  • Page 30 Hantek 6000EU Digital Oscilloscope Set Math Click “MATH” in Channel menu to set MATH channel. The MATH Setup window: ON/OFF: Turn On/Off the MATH Channel. Source A/B: Set the sources of the math channel. Operate: Set operates type of the math channel.
  • Page 31 Hantek 6000EU Digital Oscilloscope In this function, use the addition, subtraction, multiplication and FFT function to operate and analyze the waveform. Select the operate type in the Operate menu. Select source A and B. Then adjust the vertical scale and offset to view the math channel clearly. The mathematic result can be measured by the measure and the cursor.
  • Page 32 Hantek 6000EU Digital Oscilloscope Invert The invert function turns the displayed waveform 180 degrees, with respect to the ground level. When the oscilloscope is triggered on the inverted signal, the trigger is also inverted. Click “Invert” in MATH. The following picture shows the waveform before inversion: The following picture shows the waveform of inversion: USER’S MANUAL...
  • Page 33 Hantek 6000EU Digital Oscilloscope Set Reference Click “REF” in “Setup” menu to set REF channel. The Reference Channel Function: On/Off: Turn on/off the reference channel. Volt/DIV: Channel the resolution of the reference channel. Load: Load the reference waveform from the “.rfc” file from your computer.
  • Page 34: Setup Horizontal System

    Hantek 6000EU Digital Oscilloscope Note: If you turn on the “Reference” channel, the load file window will appear. 3.3 Setup Horizontal System Change Time/Div The “Time/Div” elects the horizontal Time/DIV (scale factor) for the main or the window time base The Horizontal Panel Click the blue knob can change Time/Div.
  • Page 35: Set Trigger System

    Hantek 6000EU Digital Oscilloscope In the “Format” item, set the waveform display format (Y-T, X-Y). Y -T: Show the relative relation between vertical voltage and horizontal time X -Y: Show CH1 value at X axis; CH2 value at Y axis...
  • Page 36 Hantek 6000EU Digital Oscilloscope Sweep: Set the sweep mode to Auto, Normal or Single. Auto: Acquire waveform even no trigger occurred Normal: Acquire waveform when trigger occurred. Single: Acquire waveform when trigger occurred then stop Source: You can use the trigger source options to select the signal that the oscilloscope uses as a trigger.
  • Page 37 Hantek 6000EU Digital Oscilloscope The user can also change the trigger setting on trigger panel in sidebar. When alternative trigger is on, the trigger sources come from two vertical channels. This mode can be used to observe two non-related signals. You can choose two different trigger modes for the four vertical channels.
  • Page 38 Hantek 6000EU Digital Oscilloscope Source: Set the Trigger Channel to CH1,CH2,CH3,CH4. Trigger Sync: Trigger Standard: Options Settings Comments With Video highlighted, an NTSC, PAL or SECAM Video standard video signal will be triggered. The trigger coupling is preset to AC.
  • Page 39 Hantek 6000EU Digital Oscilloscope -More: -Pulse width more than selecting pulse condition. -Less: -Pulse width less than selecting pulse condition. -Equal: -Pulse width equal to selecting pulse condition. Pulse Width: The Pulse Width adjust range is 10ns~10s. When the condition is met, it will trigger and acquire the waveform.
  • Page 40: Save/Load

    Hantek 6000EU Digital Oscilloscope 3.5 Save/Load Save Click “File” in main menu to save waveform, setups and screen. 1. Save Data Save waveform data as a type file 2. Save Setup Save the current oscilloscope setup to file 3. Save Image Save the software display window as a .bmp or .jpg file...
  • Page 41: Utility Function

    Hantek 6000EU Digital Oscilloscope the lower right corner of the screen. This function can record input waveform form CH1, CH2, CH3, CH4. Storage: Record waveform and save it as “.dfc” file. “Play Back” button: Click this button to start playing back waveform.
  • Page 42: Pass/Fail

    Hantek 6000EU Digital Oscilloscope 3.7.1 Pass/Fail Click “Pass/Fail” in “Utility” menu. The Pass/Fail window appears: The Pass/Fail function monitors changes of signals and outputs pass or fail signals by comparing the input signal with the pre-created mask. Control Setting Source: Select the Pass/Fail channel Output: Select the Pass/Fail output condition.
  • Page 43 Hantek 6000EU Digital Oscilloscope Mask Setting ertical: Set the vertical limit range Horizontal: Set the horizontal limit range “Create” button: Click this button to create Pass/Fail area according to the mask “Save” button: Click this button to save the setups to file “Load”...
  • Page 44: F/C

    Hantek 6000EU Digital Oscilloscope The Pass/Fail function display NOTE: Pass/Fall function is unavailable in X-Y mode. 3.7.2 F/C Click “F/C” in “Utility” menu to display the frequency value of the trigger channel. USER’S MANUAL...
  • Page 45: Factory Setup

    Hantek 6000EU Digital Oscilloscope 3.7.3 Factory Setup Click “Factory Setup” in “Utility” menu to load default setups When you click the Factory Setup in Utility menu, the oscilloscope displays the CH1 waveforms and removes all other waveforms. The oscilloscope set up for normal operation when it is shipped from the factory and can be recalled at anytime by user.
  • Page 46: Measure Signal

    Hantek 6000EU Digital Oscilloscope 3.8 Measure Signal 3.7.1 Cursor Menu Click “Cursor” in main menu. This method allows you to take measurements by moving the cursors 1. Source The user can set the source to CH1, CH2, CH3, CH4 and MATH.
  • Page 47 Hantek 6000EU Digital Oscilloscope The Cross cursor display window: The Cross measure result displays on status bar 2) Trace The Trace cursors appear as vertical lines on the display and measure the waveform amplitude at the point the waveform crosses the cursor.
  • Page 48 Hantek 6000EU Digital Oscilloscope 3) Vertical The Vertical cursors appear as vertical lines on the display and measure the vertical parameters. The Vertical cursor display window: The Vertical cursor measure result display on status bar 4)Horizontal The Horizontal cursors appear as horizontal lines on the display and measure the horizontal parameters.
  • Page 49: Measure Menu

    Hantek 6000EU Digital Oscilloscope The Horizontal cursor measure result display on status bar 3.7.2 Measure Menu Click “Measure” in main menu. The oscilloscope provides 20 parametric auto measurements (12 voltage and 8 time measurements). 1.Source The user can use the “Source” menu to select a measure source.
  • Page 50 Hantek 6000EU Digital Oscilloscope Minimum: Voltage of the absolute minimum level, Measured over the entire waveform Peak To Peak: Peak-to-peak = Max –Min, Measured over the entire waveform Top: Voltage of the statistical maximum level, Measured over the entire waveform...
  • Page 51 Hantek 6000EU Digital Oscilloscope The Measure Display Window: Note: The results of the automatic measurements will be displayed on the bottom of the screen. Maximum 8 results could be displayed at the same time. When there is no room, the next new measurement result will make the previous results moving left, out of screen.
  • Page 52: The Display System

    Hantek 6000EU Digital Oscilloscope 3.8 The Display System 3.8.1 Display Type Click “Type” in “Display” menu. The following figure shows the type parameters setting. If the Vectors type mode is selected, the waveform will be displayed as following figure. If the Dots type mode is selected, the waveform will be displayed as following figure.
  • Page 53: Display Grid

    Hantek 6000EU Digital Oscilloscope 3.8.2 Display Grid Click “Display” in main menu The grid shows: USER’S MANUAL...
  • Page 54: Intensity

    Hantek 6000EU Digital Oscilloscope The grid not shows: 3.8.3 Intensity Click “Display->Intensity” in main menu. The following figure shows the intensity dialog. It shows the display parameters setting. USER’S MANUAL...
  • Page 55: Grid Background Color

    Hantek 6000EU Digital Oscilloscope You can change the grid and waveform color intensity in this dialog. 3.8.4 Grid Background Color Click “Display-> Grid Background Color” in main menu. The following Settings you can change the test the background color of the display area.
  • Page 56: Color Mode

    Hantek 6000EU Digital Oscilloscope 3.8.5 Color Mode The following figure shows the type Color Mode. Click “Display-> Color Mode->Color Temperature” , you can turn on the color temperature function. Color temperature adopts the change of waveforms’ color to reflect the change of the waveforms’...
  • Page 57 Hantek 6000EU Digital Oscilloscope Click “Display-> Color Mode->Grayscale”. There are two kinds of grayscale display mode, When choosing a DPO mode for level 256 grayscale display and the max waveform capture rate to 60,000 wfm/s, but if the Acquire is on the FastAcq model,so the oscilloscope is only with 1-level intensity grading display function and the max waveform capture rate to 400,000wfm/s.
  • Page 58: Persis. Time

    Hantek 6000EU Digital Oscilloscope 3.8.6 Persis. Time Click “Display-> Persis.Time ” , to set the persistence time of the oscilloscope to 100 ms, 200 ms, 500 ms, 1 s, 5 s and 10 s or Infinite. With persistence, the oscilloscope updates the display with new acquisitions, but does not immediately erase the results of previous acquisitions.
  • Page 59: Channel Delay

    Hantek 6000EU Digital Oscilloscope in their normal color with normal intensity. 1: Variable persistence time (100 ms, 200 ms, 500 ms, 1 s, 5 s, 10s) select different persistence time, the results of previous acquisitions are erased after a certain amount of time. You can refer to the following presentation images 2:...
  • Page 60: Zoom In/Out And Drag Waveforms

    Hantek 6000EU Digital Oscilloscope -100 ns to 100 ns. 3.9 Zoom In/Out and Drag Waveforms The software will stop updating waveform after the user clicked “Stop” button. The user can change the waveform display by adjusting the scale and position.
  • Page 61: Interpolation

    Hantek 6000EU Digital Oscilloscope 3.10 Interpolation At the time base 20ns/div or faster, user can use the 3 different interpolation mode to get waveforms of different smoothness. The Step Interpolation: Linear Interpolation: USER’S MANUAL...
  • Page 62 Hantek 6000EU Digital Oscilloscope The Sin(x)/x Interpolation: Note: The default interpolation mode is Sin(x)/x. Acquisition When you acquire a signal, the oscilloscope converts it into a digital form and displays a waveform. The acquisition mode defines how the signal is digitized and the time base setting affects the time span and level of detail in the acquisition.
  • Page 63: Acquisition Modes

    Hantek 6000EU Digital Oscilloscope 3.11 Acquisition Modes There are four acquisition modes: Normal, Average, Peak Detect and High Res. Normal: In this acquisition mode, the oscilloscope samples the signal in evenly spaced intervals to construct the waveform. Average: In this acquisition mode, the oscilloscope acquires several waveforms, averages them, and displays the resulting waveform.
  • Page 64 Hantek 6000EU Digital Oscilloscope DPO: In this mode, the oscilloscope supports 256-level intensity grading display with one channel. The Max Waveform capture rate up to 60,000 wfm/s. FastAcq: In this mode, the oscilloscope supports 1-level intensity grading display with one channel. The Max Waveform capture rate up to 400,000 wfm/s.
  • Page 65 Hantek 6000EU Digital Oscilloscope ETS: Equivalent Time Sampling. A method of increasing the effective sampling rate of the scope. In a scope view, the program captures several cycles of a repetitive signal, then combines the results to produce a single waveform with higher time-resolution than a single capture.
  • Page 66: Print And Print Preview

    Hantek 6000EU Digital Oscilloscope 3.13 Print And Print Preview 1. Click “Print” in “File” menu to set the printer to print the current waveform 2. Click the “PrintPreview” in “File” menu to get into the Preview window. In “PrintPreview” window, use the “Zoom In” button and the “Zoom Out” button to change the size of the waveform graph.
  • Page 67 Hantek 6000EU Digital Oscilloscope USER’S MANUAL...
  • Page 68: Chapter 4 Application Example

    Hantek 6000EU Digital Oscilloscope Chapter 4 Application Example Simple Measurement Capturing a Single-Shot Signal The Application of the X-Y Taking Cursor Measurement USER’S MANUAL...
  • Page 69: Simple Measurement

    Hantek 6000EU Digital Oscilloscope 4.1 Simple Measurement To acquire and display a signal, please do the steps as follows: 1. Connect signal to CH1 by using probe 2. Click the button on toolbar or “Acquire -> Auto Setup” on menu.
  • Page 70: Capturing A Single-Shot Signal

    Hantek 6000EU Digital Oscilloscope 4.2 Capturing a Single-Shot Signal To capture a single event, it needs to gather some pre-test knowledge of the signal in order to set up the trigger level and slope correctly. For example, if the event is derived from 3.3V COMS logic, a trigger level of 1.2 or higher Volts should work on a rising edge.
  • Page 71 Hantek 6000EU Digital Oscilloscope pattern representing the input and the output characteristics of the circuit. 6. Adjust the scale and offset of the horizontal and vertical to a desirable waveform display. The following picture shows a typical example. 7. Apply the Ellipse Method to observe the phase difference between the two channels.
  • Page 72: Taking Cursor Measurements

    Hantek 6000EU Digital Oscilloscope 4.4 Taking Cursor Measurements Use cursors to make time and amplitude measurements on a waveform quickly. Measure the Peak Frequency or Time of the First Sine Waveform Do these steps: 1. Click “Cursor->Source”, select CH1 (select CH2 if you want measure CH2).
  • Page 73 Hantek 6000EU Digital Oscilloscope 3. Push left mouse button, and the Horizontal lines appear. 4. Drag the mouse button to the point you want to measure. 5. Release the left mouse button, the voltage difference will be shown at the status bar.
  • Page 74 Hantek 6000EU Digital Oscilloscope Trace the Amplitude: Read the details showing in the status bar. Note: Click “Cursor->Type”, select “Cross”, you can measure time and amplitude at one time. USER’S MANUAL...
  • Page 75: Chapter 5 Appendix

    Hantek 6000EU Digital Oscilloscope Chapter 5 Appendix  Appendix A: Specifications  Appendix B: General Maintenance USER’S MANUAL...
  • Page 76: Appendix A: Specifications

    Hantek 6000EU Digital Oscilloscope Appendix A: Specifications Specifications Table: Vertical Analog Channels Bandwidth 250/200/100/70MHz(-3dB) Resistance: 1MΩ ; Capacitance: 25 pF± 3pF Input Impedance Input Sensitivity 500uV/div to 10V/div Input Coupling AC/DC/GND Vertical Resolution 8 bits Memory Depth 128M/CH;62M/2CH;32M/4CH Analog Bandwidth Limit,...
  • Page 77 Hantek 6000EU Digital Oscilloscope Frequency, Period, Rise Time, Fall Time, Positive Width, Time Measurement Negative Width, Duty Cycle Cursors Measurement Horizontal ,Vertical, Track, Cross Waveform Signal Process +,- , x,÷ , FFT, Invert Voltage Range 500uV to 10V/div @ x 1 probe...
  • Page 78: Appendix B: Accessories

    Hantek 6000EU Digital Oscilloscope Appendix B: Accessories X1, X10 two passive probes. The passive probes have a 6MHz bandwidth (rated 100Vrms CAT III) when the switch is in the X1 position, and a maximum bandwidth (rated 300Vrms CAT II) when the switch is in the X10 position. Each probe consists of all necessary fittings.

Table of Contents