Further Actions In Step 7/Ncm Pc - Siemens SIMATIC IPC427D Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC427D:
Table of Contents

Advertisement

You can find additional, detailed information about the individual loader variants in the
integrated help.
Note
When loading the firmware or commissioning the module, be aware that the CP 1616
onboard takes five MAC addresses (always in direct sequence). The first two addresses are
displayed in the BIOS, in the "Peripheral Configuration" submenu of the "Advanced" menu.
Example
The lower MAC address at "Profinet" is provided for Layer 2 communication, while the
second one is used for Ethernet/PROFINET communication.
8.6.5.3

Further actions in STEP 7/NCM PC

Configuring
Your PC is now ready, although you still have to configure the SIMATIC NET communication
software. The rest of the procedure is described in the "Commissioning PC Stations" manual
(on the Windows PC that also contains STEP 7/NCM PC: Start > Simatic > Documentation >
English > Commissioning PC Stations).
SIMATIC IPC427D
Operating Instructions, 05/2017, A5E31347215-AB
Technical specifications
8.6 Hardware descriptions
141