Technical specifications
8.7 BIOS description
Entry
Internal COM1
Internal COM2
PCI - MPI / DP
Azalia internal HDMI codec
On-board Ethernet 1
Ethernet 1 Address
On-board Ethernet 2
Ethernet 2 Address
NOTICE
Ethernet interface restrictions
Support for Ethernet interface 2 is OS dependent. For WinPE-based applications (e.g.
SIMATIC IPC Image & Partition Creator), use Ethernet interface 1 and disable Ethernet
interface 2 in BIOS setup. This is practical because some programs use the second
Ethernet interface because it is the first one found on the PCI bus.
With iAMT-capable devices, the first Ethernet interface LAN1 is used to perform the AMT
functionality. In this case, the teaming functionality is blocked in Windows operating
systems. iAMT (LAN1) and Teaming (LAN1 and LAN2) are not possible simultaneously.
148
Meaning
Enables or disables the serial interface or configures it automati-
cally (Auto)
When enabled, it is possible to set the I/O base address and the
interrupt.
Enables or disables the CP5622-compatible MPI/DP interface.
Enables or disables the audio codec of the Intel onboard sound
card.
The first Ethernet interface on the motherboard is enabled.
With iAMT-capable devices, the 1st Ethernet interface is used to
execute the AMT functionality.
Onboard Ethernet 1 is PXE-capable.
Display the MAC address of Ethernet 1.
The second Ethernet interface on the motherboard is enabled or
disabled.
Onboard Ethernet 2 is PXE-capable.
Display the MAC address of Ethernet 2.
Operating Instructions, 05/2017, A5E31347215-AB
SIMATIC IPC427D