5-4-5. OP-10 BCD INPUT.
Parallel BCD input is used to change the PART to the external device.
This device make it effective to weigh a various works changing the PART with a connection of
Computer,PLC,Digital Switch.
The inside circuit of Input & Output circuit use a photo-coupler and was isolated from the external
* Recommand distance is under 10 M
* BCD code makes a denary into 4figure of a binary number
* In case PART 19 displayed with BCE CODE such as 0001 10001
▩ 15P D-Type Female Connector
When a additional input needs,
This addtional input will be used except of the external 4EA.
▩ BCD INPUT CIRCUIT
PIN NO
1
2
3
4
5
6
7
8
---------------------------------------------------------------------------------
FINE MECHATRONICS
0 = OFF, 1 = ON
SIGNAL
1×10
0
2×10
0
4×10
0
8×10
0
1×10
1
2×10
1
4×10
1
8×10
1
FS8000
PIN NO
9
EARTH (GND)
10
11
AID INPUT 1
12
AID INPUT 2
13
AID INPUT 3
14
AID INPUT 4
15
EARTH (GND)
SIGNAL
52