5-4-3I OP -06 Electric current (4 -20mA) Analog Out
* The voltage output occurs proportionally the voltage according to the size of a weight
In 4mA ~20mA.
* The type of voltage output can be changed according to SET UP F60
▩ Specification
output Voltage
Precision
Min Impedence
▩ 9P D-TYPE Female & Current out circuit
▩ Adjustment
* The resistor must be used with enough power consumption.
If you used 500 ohm resistor,
2
W = i
R = (0.02)
So,the rate of resistor must be used over than 1/2 watt by 0.2 watt power
* Absolutly do not connect above Lo(-) line to GND line,body GND
Or any similar devices.
▩ How to calibrate for output rate bewteen 4mA and 20mA.
The current out is to 4 mA when the weight is displayed 0 kg in indicator.
The current out is to 20 mA when the weight is displayed max.capacity in indicator.
If analog output is not correct,
You can make a fine adjustment with VR1(zero adjustment) and VR2(span adjustment)
On analog pc board by multi meter.
---------------------------------------------------------------------------------
FINE MECHATRONICS
4 20 mA DC Current out
Max 1/3000
Under 500 Ω
2
x 500 = 0.2 Watt
Because it is -12V,not ground (0V).
FS8000
No 1 +
No 5 -
consumption.