ERR--07
※
①Cause : In case it was deviated from a range of value which can be set by SET UP,
②Adjust : Please input the contents of SET UP again.
ERR--10
※
①Cause : In case the record device of Memory or Hardware was not normal
②Adjust : It can be worked by a voluntary key,but it was temporary way.
So,please try to send this Indicator to the head office for A/S.
UL" (UNDER LOAD)
※ "
①Cause : In case the connection of a Load cell was not normal or a Load cell was broken.
②Adjust : Pleare refer to the part related with a Load cell or CHAPTER 3 ZERO ADJUSTMENT.
OL" (OVER LOAD)
※ "
①Cause : In case the connection of a Load cell was not normal or a Load cell was broken.
②Adjust : Pleare refer to the part related with a Load cell or Remove a excess weight.
---------------------------------------------------------------------------------
FINE MECHATRONICS
FS8000
26