FINE mechatronics FS-8000 Instruction Manual page 44

Digital weighing indicator
Table of Contents

Advertisement

► CONNECTOR: CHAMP 57-40500(Ampheonol) (Female)
► TTL OPEN-COLLECTOR OUTPUT
► HOLD INPUT should be connected with OPEN COLLECTOR TYPE or Switch Earth.
► And OUTPUT DATA will hold while HOLD INPUT
Weight DATA
BUSY
► Signal Logic
Weight BCD DATA OUTPUT → Positive)/Negative .
POLARITY OUTPUT
OVER
BUSY
BCD HOLD
▩ BCD OUTPUT CIRCUIT
Inner Circuit
COMMON(GND)
vcc
+12V
INPUT
► OUTPUT CIRCUIT IS OPEN COLLECTOR TYPE
► If output demand TTL LEVEL ,insert full up - resistance to a borad of BCD OPTION
► When inserting a fullup resistance ,please change 5v ∼ 30V in 37,39 NO
Resistance and Voltage .
5V = 1 kΩ , 10V = 2 kΩ , 15V = 2.7kΩ , 24V = 5 kΩ
---------------------------------------------------------------------------------
FINE MECHATRONICS
→ " OVER " = L
→ " BUSY " = L
→ " HOLD " = L (INPUT)
Other equipment
FS8000
→ " ― "
= L
+V
FULLUP RESISTANCE
OUTPUT
+V
Voltage
Current
30V
max.
30mA max.
44