Analog Out - FINE mechatronics FS-8000 Instruction Manual

Digital weighing indicator
Table of Contents

Advertisement

5-4-3 OPTION-05/06 ANALOG OUT
* This option is a device to output and convert the weight value to External device(Recorder P.L.C
Center control so) controlled by Analog Signal.
* The voltage output occurs proportionallly the voltage according to the size of weight in 0V ~10V.
* The current output occurs proportionallly the current according to the size of weight in 4mA~20mA
* The precision of Analog output is Max.1/3000
So,Unavailable to use it in case of high precision over 1/3000
F60-
F61-
F62-
F63-
---------------------------------------------------------------------------------
FINE MECHATRONICS
Analog Out Weight Selecting
displayed Weight value
1
GROSS Weight
2
NET Weight
Gross or Net Weight can be different with weight value displayed
Analog Out standard Selecting
MAx.Weight Standard
1
Standard value setup by F-63

Analog Out

Positive out : 4mA, 0V while weight is 0
1
Negative out : 20mA, 5V, 10V while weight is 0
Analog Out Standard Weight Selecting.
Analog max out value when weight setup.
* first Setting 000000
FS8000
POLARITY
46