Electrical Specifications for Oracle Database Appliance
Version 1 and Models X3-2, X4-2 and X5-2
Item
Oracle Database Appliance
Version 1
Server node
1270W at 100-120 VAC
power supply
1370W at 200-240 VAC
output rated
maximum
Server node
12A at 110-127 VAC
AC power
7A at 200-240 VAC
13A at 100 VAC (Japan only)
Storage shelf
Not supported
power supply
output rated
maximum
Storage shelf
Not supported
AC Power
Power usage
Not available
Environmental Specifications
This section describes the environmental specifications for a single, non-racked Oracle
Database Appliance.
Environmental Specifications for Oracle Database Appliance
X6-2 Series
Item
Oracle Database
Appliance X6-2S
°
°
Operating
5
C to 35
C (41
°
temperature
95
F).
Oracle Database Appliance
X3-2/X4-2
600W at 100-127 VAC
600W at 200-240 VAC
7.2A at 100-127 VAC
3.4A at 200-240 VAC
580W at 100-127 VAC
580W at 200-240 VAC
8A at 100-127 VAC
3A at 220-240 VAC
Server node
■ X4-2 maximum: 439W
X4-2 typical: 164W
■ X3-2 maximum: 551W
X3-2 typical: 178W
Storage shelf
■ Maximum: 699W
■ Typical: 325W
Oracle Database
Appliance X6-2M
°
°
°
°
F to
5
C to 35
C (41
F to
°
95
F)
Chapter 2 • Overview of Oracle Database Appliance
Oracle Database Appliance Specifications
Oracle Database Appliance
X5-2
600W at 100-127 VAC
600W at 200-240 VAC
7.2A at 100-127 VAC
3.4A at 200-240 VAC
580W at 100-127 VAC
580W at 200-240 VAC
8A at 100-127 VAC
3A at 220-240 VAC
Server node
■ Maximum: 727W
■ Typical: 508W
Storage shelf
■ Maximum: 699W
■ Typical: 469W
Oracle Database
Oracle Database
Appliance X6-2L
Appliance X6-2-HA
°
°
°
°
5
C to 35
C (41
F to
5
C to 35
°
°
95
F)
95
°
°
C (41
F to
F)
51