Pin Assignment Of Rf340R Rs422 Interface; Led Operating Display; Ensuring Reliable Data Exchange - Siemens SIMATIC Ident System Manual

Identification rfid systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

5.4.1.3

Pin assignment of RF340R RS422 interface

Pin
5.4.1.4

LED operating display

The operational statuses of the reader are displayed by the LEDs. The LED can adopt the
colors green, red or yellow and the statuses off , on
Table 5- 12
Color
Only in the "with presence" mode.
1)
5.4.1.5

Ensuring reliable data exchange

The "center point" of the transponder must be situated within the transmission window.
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
Pin
Assignment
Device end
8-pin M12
1
+ 24 V
2
- Transmit
3
0 V
4
+ Transmit
5
+ Receive
6
- Receive
7
Unassigned
8
Earth (shield)
LED operating display on the reader
Meaning
Operating voltage present, reader not initialized or antenna switched off
Operating voltage present, reader initialized and antenna switched on
Transponder present
1)
Error has occurred, the type of flashing corresponds to the error code in the
table in the section Error codes. The optical error display is only reset if the
corresponding reset parameter ("option_1", see FC 45 / FB 45 documentation,
section Input parameters) is set.
5.4 SIMATIC RF340R/RF350R
, flashing :
Readers
137

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf300

Table of Contents