Readers
5.5 SIMATIC RF340R/RF350R - second generation
5.5.1.6

Metal-free area

The RF340R can be flush-mounted in metal. Allow for a possible reduction in the field data.
To avoid any influence on the field data, the distance "a" should be kept to.
a ≥
Figure 5-18
5.5.1.7

Minimum distance between RF340R readers

RF340R side by side
D ≥
D ≥
Figure 5-19
154
20 mm
Metal-free area for RF340R
200 mm (with 2 readers)
250 mm (with more than 2 readers)
Minimum distance between RF340R readers
System Manual, 07/2016, C79000-G8976-C345-0x