Download  Print this page

Siemens SIMATIC Ident System Manual Page 140

Identification rfid systems.
Hide thumbs

Advertisement

Readers
5.4 SIMATIC RF340R/RF350R
Mechanical specifications
Housing
Recommended distance to metal
Supply voltage, current consumption, power loss
Supply voltage
Typical current consumption
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
Shock-resistant to EN 60721-3-7, Class 7 M3
Vibration-resistant to EN 60721-3-7, Class 7 M3
Torsion and bending load
Design, dimensions and weight
Dimensions (L x W x H)
Weight
Type of mounting
Cable length for RS-422 interface, maximum
LED display design
Standards, specifications, approvals
Proof of suitability
140
Material
Color
During operation
During transportation and storage
Plastic PA 12
Anthracite
0 mm
24 VDC
100 mA
-25 to +70 ℃
-40 to +85 ℃
IP67
50 g
20 g
Not permitted
75 x 75 x 41 mm
250 g
2 x M5 screws;
1.5 Nm
1000 m
3-color LED
Radio to R&TTE directives EN 300330,
EN 301489, CE, FCC, UL/CSA,
Ex approval
System Manual, 07/2016, C79000-G8976-C345-0x
6GT2801-2AB10
SIMATIC RF300