Siemens SIMATIC Ident System Manual page 80

Identification rfid systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Planning the RF300 system
4.3 Installation guidelines
Reader RF350R with ANT 12 and with ISO transponders (MDS E)
Table 4- 45
Transponder
MDS E623
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
Reader RF350R with ANT 18 and with RF300 transponders
Table 4- 46
Transponder
RF320T
RF330T
RF340T
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
Values of > 100 % can occur if transponders were developed specifically for mounting in/on metal-
2)
lic surroundings.
80
Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 12
without metal
on metal; distance 0 mm
flush-mounted in metal;
distance all round 0 mm
Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 18
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 10 mm
Flush-mounted in metal;
without surrounding clearance
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
ANT 12 without metal
100
90
70
ANT 18 without metal
100
85
75
100
120
2)
115
2)
95
100
65
60
System Manual, 07/2016, C79000-G8976-C345-0x
ANT 12 mounted in met-
al
(0 mm all-round)
80
75
60
ANT 18 mounted in met-
al
(10 mm all-round)
65
55
45
85
100
95
90
85
60
55
SIMATIC RF300

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf300

Table of Contents