4.5 Adjustment and Setup Items
4.5.1 Adjustment Item List
iPF5100
The following adjustment procedures need to be performed when parts have been replaced or remove and then reinstalled:
4.5.2 Procedure after Replacing the Feed Roller HP Sensor or Feed Roller Encoder
iPF5000
Procedure after replacing the feed roller HP sensor or feed roller encoder
Feed roller eccentricity is factory-adjusted (correction of variation in the paper feed amount per rotation). It is necessary to adjust feed roller eccentricity after re-
placing the feed roller HP sensor or feed roller encoder.
In the service mode, perform automatic adjustment of feed roller eccentricity.
Service mode : SERVICE MODE > ADJUST > PRINT PATTERN > LF TYNING
Media type : Photo glossy paper
Media size : Media having awidth equal to or larger than that of A2-size paper
4.5.3 Procedure after Replacing the Carriage Unit or Multi Sensor
iPF5000 / iPF5100
a) Multi Sensor Recalibration
Since multi sensors have individual electrical specificity, the following are recalibrated at the factory, namely, the optical axis of the sensor, the sensor gain for
measuring the printhead height and sensor reproduction. Accordingly, carry out the following adjustments in the service mode whenever replacing the carriage unit
or multi sensor.
- Service mode : SERVICE MODE > ADJUST > GAP CALIB.
- Service mode : SERVICE MODE > ADJUST > PRINT PATTERN > OPTICAL AXIS
Media type : Photo glossy paper
Media size : Media having a width equal toor larger then that of A2-size paper
The multi sensor reference plate must be replaced at the same time whenever the carriage or the multi sensor is being replaced.
Adjustment item
Multi sensor recalibration
Adjusting wire roller
Head management sensor recalibration
T-4-1
Adjustment timing
Multi sensor replacement/removal
Carriage unit replacement/removal
Wire guide replacement/removal
Carriage unit replacement/removal
Head management sensor replacement/removal
Carriage unit replacement/removal
Chapter 4
0016-9220
0012-6480
0012-6486
4-71