f) SETTING
Make various settings.
1) Pth
Turn on or off the head pulse rank control function.
Default: OFF
2) RTC
Set RTC (real time clock) after replacing the lithium battery on the main controller PCB.
DATE
TIME
3) PV AUTO JUDGE
Sets ink saver mode.
Default: OFF
4) CAS. PRE PRINT
Turn on to perform preprinting on cassette pickup.
Default: OFF
g) INITIALIZE
Clear the [DISPLAY] histories, [ADJUST] settings, [COUNTER] values, and other parameters.
Display
WARNING
ERROR
ADJUST
W-INK
PURGE
INK-USE CNT
CUTTER-CHG CNT
W-INK-CHG CNT
HEAD-CHG R CNT
HEAD-CHG L CNT
PARTS-CHG
PARTS xx
CNT
PARTS
PARTS xx
COUNTER
Display
yyyy/mm/dd
Set date
hh:mm
Set time
Initialize the history of WARNING.
(All displayed contents of [DISPLAY] > [WARNING] will be initialized.)
Initialize the history of ERROR.
(All displayed contents of [DISPLAY] > [ERROR] will be initialized.)
Initialize the value of band adjustment (by user) and head adjustment.
The automatically adjusted value will not be initialized.
Initialize the remaining capacity (%) of the maitenance cartridge.
(Clear [COUNTER] > [PRINTER] > [W-INK])
Initialize the counter related to purge unit.
(Clear [COUNTER] > [PURGE])
Initialize the consumption amount of ink.
(Clear [COUNTER] > [INK-USE2], and count up [COUNTER] > [CLEAR] > [CLR-INK CONSUME])
Initialize the cutter unit replacement frequency.
(Clear [COUNTER] > [EXCHANGE] > [CUTTER EXC.], and count up [COUNTER] > [CLEAR] > [CLR-CUTTER
EXC.])
Initialize the maintenance cartridge replacement frequency.
(Clear [COUNTER] > [EXCHANGE] > [MTC EXC.], and count up [COUNTER] > [CLEAR] > [CLR-MTC EXC.])
Initialize the printhead R replacement frequency.
(Clear [COUNTER] > [EXCHANGE] > [HEAD R EXC.], and count up [COUNTER] > [CLEAR] > [CLR-HEAD R
EXC.])
Initialize the printhead L replacement frequency.
(Clear [COUNTER] > [EXCHANGE] > [HEAD L EXC.], and count up [COUNTER] > [CLEAR] > [CLR-HEAD L
EXC.])
xx: Unit number of consumable parts
(For details, refer to "Maintenance and Inspection" > "Consumable Parts")
Initialize the consumable part replacement frequency.
(Clear [COUNTER] > [EXCHANGE] > [UNIT x EXC], and count up [COUNTER] > [CLEAR] > [CLR-UNIT x
EXC.])
xx: Unit number of consumable parts
(For details, refer to "Maintenance and Inspection" > "Consumable Parts")
Initialize the counter amount of the consumable parts.
(Clear [COUNTER] > [PARTS CNT.] > [PARTS x])
* After replacing the consumable part, be sure to execute this menu.