2) Remove the exhaust filter[2] while pushing the hook[1].
k) Mist filter
Removing the mist filter
1) When removing the mist filter[2], open the top cover, and then remove the right circle cover.
2) Removing the screw[1], and then remove the mist filter[2].
l) Right cover
Removing the right cover
1) When removing the right cover[3], open the top cover, and then remove the roll feed unit, right circle cover, right upper cover, operation panel, exhaust filter,
and lower rear cover.
2) Remove the six screws[1] and hook[2], and then remove the right cover[3].
F-4-42
F-4-43
[3]
[1]
[2]
F-4-44
[1]
[2]
[2]
[1]
[1]
Chapter 4