Chapter 4

4.5 Adjustment and Setup Items

4.5.1 Procedure after Replacing the Feed Roller HP Sensor or Feed Roller Encoder

Procedure after replacing the feed roller HP sensor or feed roller encoder

Feed roller eccentricity is factory-adjusted (correction of variation in the paper feed amount per rotation). It is necessary to adjust feed roller eccentricity after re-
placing the feed roller HP sensor or feed roller encoder.
In the service mode, perform automatic adjustment of feed roller eccentricity.
Service mode : SERVICE MODE > ADJUST > PRINT PATTERN > LF TUNING
Media type : Photo glossy paper
Media size : Media having awidth equal to or larger than that of A2-size paper

4.5.2 Procedure after Replacing the Carriage Unit or Multi Sensor

a) Multi Sensor Recalibration
Since multi sensors have individual electrical specificity, the following are recalibrated at the factory, namely, the optical axis of the sensor, the sensor gain for
measuring the printhead height and color reproduction. Accordingly, carry out the following adjustments in the service mode whenever replacing the carriage unit
or multi sensor.
The multi sensor reference plate must be replaced at the same time whenever the carriage or the multi sensor is being replaced.
4-22
Bearing
Permalube G No.2
approx. 24mg
Feed roller
Feed roller
Feed roller
Permalube G No.2
approx. 24mg
F-4-41
F-4-42
Permalube G No.2
approx. 24mg
Permalube G No.2
approx. 24mg