Omron NV Series Programming Manual page 161

Programmable
Hide thumbs Also See for NV Series:
Table of Contents

Advertisement

Line Graphs
140
5. Double-click the line graph part and change the basic setup.
6. Click the Display Tab and set the attributes.
7. Click the Element Setup Tab and double-click row 0.
Section 7-10
Double-click the parts num-
ber LGO on the base screen,
and make the following set-
tings.
Function:
Data Log
Group No.:
0
Number of Lines: 1
Graph Type:
Pen Move
Number of
Scrolls:
1
Direction:
Stop Update:
Off
Display Points:
80
Click the Display Tab and
make the following settings.
Display Data Plot
Interval (Dot):
1
Background Color:
White
Display Frame:
Whole
Scale
Horizontal Line:
On
Number of Divisions: 5
Vertical Line:
On
Number of Divisions: 5