Omron NV Series Programming Manual page 156

Programmable
Hide thumbs Also See for NV Series:
Table of Contents

Advertisement

Line Graphs
Description of Operation
The PT reads data from the PLC at the specified interval, and then saves it
into internal memory. The values saved in internal memory in the PT are dis-
played by the line graph part. The graph is updated at the specified interval.
PT Screen
90
80
50
40
30
20
10
Graph Type
There are two types of line graphs.
Pen Move:
Once the display area is full, the graph is scrolled by a set
amount equal to a few minutes of data, after which graph draw-
ing is resumed.
Sheet Move: As monitoring is performed, the graph is drawn in the specified
direction.
■Broken-Line Graph
A bit in the PLC is used as a trigger to prompt the NV-Series to batch-read
multiple words of data from the PLC.
Description of Operation
When the specified bit in the PLC turns ON, the PT reads data from the PLC.
The data is displayed on the line graph. While the bit is ON, the graph is con-
stantly updated.
PT Screen
90
80
50
40
30
20
10
View
PT
Monitoring is
performed at
the specified
interval.
Internal memory in PT
20
40
30
50
80
10
90
PT
Specified bit
Internal memory in PT
20
40
30
50
Batch read
80
10
90
Section 7-10
PLC
D100
PLC
All the data is
read at the
same time.
ON
D100
20
D101
40
D102
30
D103
50
D104
80
D105
10
D106
90
135

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nv3w seriesNv4w seriesNv3q series

Table of Contents