Omron NV Series Programming Manual page 107

Programmable
Hide thumbs Also See for NV Series:
Table of Contents

Advertisement

Setting the NV Configuration from the NV-Designer
Item
Clock
Clock
Transfer Outside
(NV4W/NV3Q
only)
*1
Automatic Backlight Off
Key Press Sound
*2
Battery Error Display
(NV4W/NV3Q only)
*3
File Compression
System Menu Language
Startup of Multi-Language
*4
Exchange
86
Sets the reference for the clock displayed on the PT. For the NV4W/NV3Q, set either the
NV clock or the PLC clock. For the NV3W, specify if PLC data is to be accessed for the
clock displays.
Sets whether to transfer displayed clock data to an external device, such as the PLC. If
you specify accessing PLC data, a setting item will be displayed to enter the communica-
tions address. Set the address in the PLC from which clock data will be output.
Refer to Setting the Clock Function on page 87 for details.
Sets whether to automatically turn OFF the backlight.
• Off
The backlight is not automatically turned OFF.
• On
The backlight is automatically turned OFF. If the On Option is selected, a box to specify
the amount of time taken until the backlight is automatically turned OFF will be dis-
played. Set time to between 1 and 30 minutes.
Sets the sound that is made when the screen is touched.
• Disable
The operation sound is disabled.
• Enable
The operation sound is enabled.
Sets whether to display the battery low mark (
• Off
The battery low mark is not displayed.
• On
The battery low mark is displayed when the battery charge is low and when it is out of
charge.
Sets whether to compress the data transferred to the PT.
• Off
Screen data is not compressed.
• On
Screen data is compressed.
Sets the language for the System Menu. Select one of the following from the pull down
menu.
• English (default)
• Japanese
Sets whether to specify the language number from the PLC when using the multi-lan-
guage exchange function.
• Off
Language numbers are not specified from the PLC.
• On
Language numbers are specified from the PLC. If you specify accessing PLC data, a
setting will be displayed to enter the communications address (2 words). Set the address
in the PLC from which the language number will be set. The following two words are
used for the communications addresses.
First word: Language number specified by the PLC (sent from PLC to PT)
First word +1: Number of language currently displayed on PT (sent from PT to PLC)
For details, refer to 8-7 Switching the Display Language and to information on switching
the display language in the NV-Designer online help.