Bkm-10R Monitor Control Unit (Optional) - Sony BVM-D32E1WA Maintenance Manual

Trinitron color video monitor
Hide thumbs Also See for BVM-D32E1WA:
Table of Contents

Advertisement

Location and Function of Parts
7 REMOTE 1 connectors (female, D-sub 9-pin)
REMOTE 1
REMOTE 1 IN connector
IN
OUT
REMOTE 1 OUT connector
These are RS-485 serial interface connectors, used for
connecting two or more BVM-Dxx, BVM-xxE/F/G
and HDM-xxE series monitors.
The IN and OUT connectors form a loop-through
connection.
Connect two monitors using a cable with D-sub 9-pin
plugs such as an RCC-5G (not supplied) as shown in
the figure.
Monitor 1
Monitor 2
REMOTE 1
REMOTE 1
IN
IN
OUT
OUT
Cable with D-sub 9-pin plugs (not supplied)
8 REMOTE 2 connector (female, D-sub 9-pin)
Forms a parallel switch and controls the monitor
externally. The pin assignment and factory setting
function assigned to each pin are given below.
5
1
9
6
14
Pin number
Function
1
Set input signal channel 1 (numeric keypad
function)
2
Set input signal channel 2 (numeric keypad
function)
3
Select sync signal (SYNC button function)
4
Set the screen to monochrome, or set for
automatic switching based on the input signal
(MONO MODE button function)
5
Safe area on/off (SAFE AREA button
function)
6, 7
Not connected
8
Tally lamp on/off
9
Ground
All pin function assignments can be changed with the
REMOTE menu.
For information about the REMOTE menu, see " [C2]
Assigning the Remote Control Functions (SET UP 2) —
REMOTE Menu" on page 40.
To switch each function between on and off or
between enable and disable, change pin connections in
the following way.
ON or enabled: Short each pin and pin 9 together.
OFF or disabled: Leave each pin open.
9 ISR (Interactive Status Reporting) connector
(female, D-sub 9-pin)
Connect to the ISR system.
!º CONTROL UNIT connector (female, D-sub 9-
pin)
Connects the BKM-10R Monitor Control Unit using a
cable with D-sub 9-pin plugs such as an RCC-5G/10G/
30G (not supplied) or the cable supplied with the
BKM-32H/34H Monitor Control Unit Attachment Kit.

BKM-10R Monitor Control Unit (Optional)

This manual explains the location and function of parts
and controls of the optional BKM-10R Monitor
Control Unit. The explanation applies to the optional
BKM-11R Monitor Control Unit.
1 Monitor memory card insertion slot
2 SHIFT button
3 Function buttons
4 Menu operation
buttons
1 Monitor memory card insertion slot
Insert the BKM-12Y Monitor Memory Card (optional).
For inserting/ejecting the monitor memory card, see page
20.
2 SHIFT button
Press to select one of the two functions designated to
the function buttons 3.
Each time the SHIFT button is pressed, the LED turns
on (SHIFT ON: lit in amber) and off (SHIFT OFF).
SHIFT OFF: The functions indicated above the
function buttons can be used (the LED of the
function button lits in green).
SHIFT ON: The functions indicated below the
function buttons can be used (the LED of the
function button lits in amber).
3 Function buttons
Change the operation conditions for the monitor.
Each time the button is pressed, the LED turns on and
turns off, and the operation conditions are changed.
Each button has two functions. Select one of the two
functions by pressing the SHIFT button 2. When the
SHIFT button is set to ON, the LED lights in amber,
and when the SHIFT button is set to OFF, the LED of
each button lights in green.
For the functions of the function buttons in case of SHIFT
OFF and SHIFT ON, see pages 17 and 18.
Note
If you press the UP/DOWN buttons or ENTER button
on the Monitor Control Unit quickly and repeatedly, it
may cause the monitor to go out of control. In this
case, turn the PHASE, CHROMA or another
MANUAL adjustment knob to restore control.
5 POWER switch
6 DEGAUSS button
7 DISPLAY UNIT
connector (rear)
8 Numeric keypad
9 MANUAL adjustment
buttons and knobs
4 Menu operation buttons
MENU button: Press to display the monitor
UP
MENU
menus.
UP/DOWN buttons: Press to select the
ENTER
DOWN
items and setting values.
ENTER button: Press to confirm the items
and values entered (Ent button on the
numeric keypad 8 has the same function).
For more information about menu operation, see "Basic
Menu Operations" on page 22.
5 POWER switch
Press to turn on/off the monitor. By setting with the
ADDRESS menu, it is possible to turn on/off the
power of the specified monitors only, or of all
monitors at the same time.
Note
When the monitor is turned on, "INITIALIZING" is
displayed. While it is displayed, the monitor cannot
accept commands from the BKM-10R/11R Monitor
Control Unit or the equipment connected to the serial
REMOTE 1 connector.
For information about the ADDRESS menu, see "Selecting
the Monitor to Control — ADDRESS Menu" on page 60.
(continued)
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvm-d32e1weBvm-d32e1wu

Table of Contents