B Adjusting the Color Temperature — COLOR TEMP ADJ Menu
[B1321] MONITOR ADDRESS menu
Select STD, COL1, COL2, or CH SET. ÷ Copy is
carried out.
STD: Copy common data.
COL1: Copy common data.
COL2: Copy common data.
CH SET: Copy data from a particular channel. Enter
the number of the channel from which the data will
be copied.
[B133] MEMORY CARD menu
Select the file name. ÷[B1331]
FILE NAME: Select the file name.
Note
The input signal is not displayed during the data
loading.
[B1331] FILE NAME menu
Select STD, COL1, COL2, or CH SET of the memory
card data. ÷ Copy is carried out.
STD: Copy common data.
COL1: Copy common data.
COL2: Copy common data.
CH SET: Copy data from a particular channel. Enter
the number of the channel from which the data will
be copied.
[B14] TRIM menu
Finely adjust the gain and bias by selecting ADJUST.
ADJUST: Adjust the gain and bias. To shift between
gain adjustment and bias adjustment, press UP/
DOWN buttons. Use appropriate knobs in each
adjustment as described below. After the
adjustment, press the ENTER or Ent button to
confirm the adjusted values.
RED: CONTRAST KNOB (Adjust the R gain or
bias with the CONTRAST knob.)
GREEN: BRIGHT KNOB (Adjust the G gain or
bias with the BRIGHT knob.)
BLUE: CHROMA KNOB (Adjust the B gain or
bias with the CHROMA knob.)
LUMINANCE: PHASE KNOB (Adjust luminance
with the PHASE knob.)
To reset RED/GREEN/BLUE to the value
before adjustment
When you are adjusting the gain or bias, you can
reset the setting to the one before adjustment by
pressing the corresponding MANUAL button.
To reset all of settings at the same time, press the
PHASE button.
34
TRIM: Select whether to add the fine adjustment to
the original setting (gain and bias set in MANUAL
menu [B11]).
APPLY: Adds the fine adjustment to the original
setting.
When APPLY is selected, "XX/TRIM" (XX:
the selected color temperature among STD,
COL 1 or COL 2) appears on the left top on the
COLOR TEMP ADJ menu.
NOT APPLY: Reset the setting to the original
setting (gain and bias set in MANUAL menu
[B11]).
SIGNAL: Select the white signal to be used for
adjustment.
INT: Use an internal signal. Simultaneously with
the adjustment of the gain and bias, the 100 IRE
and 20 IRE signals are automatically switched.
EXT: Use an external input signal. When adjusting
the gain and bias, input the proper signal.
Note
Even if NOT APPLY of the TRIM item is selected,
pressing the ENTER or Ent button to confirm the
adjusted values results in that APPLY will be selected.
[C1]
Setting the Input Configuration (SET UP 1)
— INPUT CONFIGURATION Menu

Overview

Data pertaining to the input signals are set with the
INPUT CONFIGURATION menu.
When a channel number (1 to 90) is entered with the
numeric keypad, it is then possible to set which input
connector on the rear panel will be assigned to that
channel number, and select the type of signal that will
be connected.
The following data can be set with the INPUT
CONFIGURATION menu.
• Assigning the signal FORMAT
• Assigning the SLOT NO
• Assigning the INPUT NO (input connector
number)
• Selecting the YC SEP (separation) filter
• Selecting the SYNC MODE
• Selecting the SCREEN MODE
• Selecting the SAFE AREA DISPLAY
• Setting the SAVE AREA MODE
• Activating/deactivating the APERTURE
adjustment
• Assigning the APERTURE VALUE
• Turning on/off the FILTER operation for
monochrome display
• Assigning CHANNEL NAME
• Selecting the picture CONTROL settings
• Setting the COLOR TEMP (temperature)
• Adjusting H PHASE
• Assigning the number of active scanning lines of
1125/60I SYSTEM
• COPYing FROM other data
Note
Data copy is impossible between monitors other than
BVM-DxxE/DxxF series.
Channels 91 to 99 assignment
The channel numbers from 91 to 99 are assigned to
internal signals.
091: PLUGE signal (Picture Line Up Generating
Equipment)
092: 20% gray signal
093: 100% white signal
094: five-step gray scale signal
095: cross hatch signal
096: cross hatch signal
097: dot signal
098: cross hatch signal
099: 0% black signal
Assigning slot and connector numbers
Set which input connector on which slot will be
assigned to the current channel. The slots are numbered
from the left, as seen when facing the rear panel, with
the REMOTE connectors slot being number 1, the
input option slots numbers 2 to 5, and the analog input
connectors slot being number 6. The connectors for
each slot are numbered 1 to 6 (from the top).
Assigning the signal type and format
The signal type and format which can be assigned to
each channel number vary, depending on what
adaptors (not supplied) are installed in the rear panel.
To assign serial digital signals
Serial digital signals can be assigned to the serial
digital input connectors on the BKM-20D/21D/22X/
41HD/42HD adaptors.
You need to install one of the BKM-20D (for
component signals only), BKM-21D, BKM-41HD or
BKM-42HD adaptors with a serial digital signal
decoder to the rear panel of the monitor.
To assign analog composite signals
Analog composite signals can be assigned to any
analog input connectors on the BKM-20D/21D/22X or
any input connectors on the BKM-24N/25P/26M/27T/
28X/48X.
You need to install one of the following decoder
adaptors.
To assign NTSC signals: BKM-21D/24N/27T
To assign PAL signals: BKM-21D/25P/27T
To assign PAL-M signals: BKM-26M
To assign SECAM signals: BKM-27T
To assign Y/C signals
Y/C signals can be assigned to any input connectors on
the BKM-24N/25P/26M/27T/28X/48X.
You need to install one of the following decoder
adaptors.
To assign NTSC signals: BKM-24N/27T
To assign PAL signals: BKM-25P/27T
To assign PAL-M signals: BKM-26M
To assign analog component or RGB signals
Analog component and RGB signals can be assigned
to any input connectors except the serial digital signal
input connectors on the BKM-20D/21D/22X/41HD/
42HD.
35