Assignment Of The Terminal Strip X2A - KEB COMBIVERT G6 Instructions For Use Manual

Installation g6 control analog/digital
Table of Contents

Advertisement

CONTROL CIRCUIT ANALOG/DIGITAL

3.3.2 Assignment of the terminal strip X2A

2
4
1
3
PIN
Name
Description
Digital mass; Reference potential for digital inputs/out-
1
0V
puts and U
2
U
Input external voltage supply
in
3
0V
like pin 1
4
U
Voltage output for the control of the digital inputs
out
5
RST
Reset
6
ST
Control release
*)
7
R
Reverse direction of rotation
8
F
Forward direction of rotation
9
I2
Digital input 2
10
I1
Digital input 1
11
I4
Digital input 4
12
I3
Digital input 3
13
O2
Digital output 2
14
O1
Digital output 1
15
0V
like pin 1
16
CRF
Reference voltage for setpoint potentiometer
17
AN1-
-Analog input 1
18
AN1+
+Analog input 1
19
AN2-
-Analog input 2
20
AN2+
+Analog input 2
Analog mass; Reference potential for analog inputs and
21
COM
outputs
20
6
8
10
12
14
5
7
9
11
13
in
16
18
20
22
24
15
17
19
21
23
26
28
30
32
25
27
29
31
Specifications
U=24 VDC +20 %/-15 %
I
=400 mA
max
U=24 V ±25 %
I
=100 mA
max
(I
=Pin 4+32)
max
8 digital inputs according to
IEC61131-2 type 1
„0" = -3...5 VDC
„1" = 15...30 VDC
Scan time ≤ 2 ms
2 digital transistor outputs
PNP
U=24 VDC ±25 %
I
=50 mA ohmic load for
max
O1+O2
max switching frequen-
cy = 250 Hz
10 VDC +5 %; I
=4 mA
max
adjustable:
0...±10 V (R
=55 kΩ)
i
0...±20 mA (R
=250 Ω)
i
4...20 mA (R
=250 Ω)
i
Resolution: 10 Bit + sign
Scan time ≤ 2 ms
continued on the next page