2.2

Control board Servo

2.2.1 Assignment of
Terminal Strip X2A
PIN Function
Analog inputs
1
+ Set value input 1
2
- Set value input 1
3
+ Analog input 2
4
- Analog input 2
Analog outputs
5
Analog output 1
6
Analog output 2
Voltage supply
7
+10 V Output
8
Analog Mass
9
Digital inputs
10 Fixed Speed 1
11 Fixed speed 2
12 External fault
13 -
14 Limit switch forward
15 Limit switch reverse
16 Control release / Reset
17 reset
Transistor outputs
18 Speed dependent
19 Ready signal
Voltage supply
20 24 V-Output
21 20...30 V-Input
22
Digital Mass
23
Relay Outputs
24 NO contact 1
25 NC contact 1
26 Switching contact 1
27 NO contact 2
28 NC contact 2
29 Switching contact 2
GB - 6
1 2 3 4 5 6 7 8 9
Name
Description
AN1+
0...±10 VDC ^ 0...±CP.22
AN1-
AN2+
0...±10 VDC ^ 0...±100 %
AN1-
Analog output of the real speed
ANOUT1
0...±10 VDC ^ 0...±3000 rpm
Analog output of the apparent current
ANOUT2
0...10 VDC ^ 0...2 x IN
CRF
Reference voltage for setpoint potentiometer
COM
Mass for analog in- and outputs
I1
I1+I2 = fixed speed 3 (default: 0 rpm)
I2
no input = analog set value
I3
Input for external fault stopping mode
I4
No function deposited in the CP-Mode
F
Software limit switch
R
Power modules are enabled;
ST
Error Reset at opening
RST
Reset; only when an error occurs
O1
Transistor output switched at actual speed = set speed
O2
Transistor output switched, as long as no error occurs
Uout
Approx. 24V output (max.100 mA))
Uin
Voltage input for external supply
0V
Potential for digital in-/outputs
RLA
Fault relay (default);
RLB
Function can be changed with CP.33
RLC
FLA
Run-Signal (default);
FLB
Function can be changed with CP.34
FLC
1) The reaction can be adjusted with CP.35 and CP. 36.. If the unit is defective there is no
guarantee that the software protective function will work.
X2A
10 11 12 13 14 15 16 17 18 19 20 21 22 23
1)
1)
24 25 26 27 28 29
Resolution 12 Bit
Scan time 1 ms
5 mA; Ri=100 Ω
Resolution 12 Bit
PWM frequency 3,4 kHz
Limiting frequency
Filter 1. Harmonic 178 Hz
+10 VDC +5% / max. 4 mA
13...30 V DC ±0 % stabilized
Ri=2,1 kΩ
Scan time 1 ms
at maximum
30 V DC
0.01...1 A