Banner SureCross DX80 Gateway Pro Reference Manual

Banner SureCross DX80 Gateway Pro Reference Manual

Wireless i/o network system web configurator
Hide thumbs Also See for SureCross DX80 Gateway Pro:
Table of Contents

Advertisement

SureCross™ DX80
DX80 Wireless I/O Network System Web Configurator
Reference Guide
Printed in USA
11/07
P/N 134421

Advertisement

Table of Contents
loading

Summary of Contents for Banner SureCross DX80 Gateway Pro

  • Page 1 SureCross™ DX80 DX80 Wireless I/O Network System Web Configurator Reference Guide Printed in USA 11/07 P/N 134421...
  • Page 2 All specifications published in this document are subject to change. Banner reserves the right to modify the specifications of products, prior to their order, without notice. Banner Engineering reserves the right to update or change documentation at any time. For the most recent version of any documentation, please refer to our website: www.bannerengineering.com.
  • Page 3: Table Of Contents

    Trending ..................................47 Cascade ..................................48 Calculate ..................................48 Constants ..................................49 Setup Submenu ..............................50 Config File ..................................50 Network ..................................51 User....................................53 Time and Date ................................55 Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 4 File System Error Codes ............................... 87 E-mail Error Codes ............................... 89 Floating Point Registers ............................90 Connection Status ..............................90 RTU and TCP Error Codes ..........................91 Network Connection Errors ..........................91 Index ..................................93 Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 5: Web Configurator

    Samples of SureCross network configurations 133602 Running the Site Survey and interpreting the results 136689 A guide to SureCross network basics 136214 A guide to connecting sensors to DX80 devices Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 6 SureCross™ DX80 Web Configurator Introduction Instruction Manual Notes Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 7: Login

    To change the device’s default IP address, first set up the host PC with an IP address different from the Ethernet Bridge or Gateway Pro IP addresses. (Please refer to Banner document 133116 for detailed instructions on setting up the host computer’s network IP address.) For example, change the PC host IP address to: 192.168.0.2.
  • Page 8: Changing The Device Ip Address

    HTTP Port, Modbus Server Port, Telnet Port, or EtherNet/IP Enabled settings. Cycle power to the Ethernet Bridge or Gateway Pro to complete this update. After the device powers up, the changes should be registered. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 9: Get All Command

    Save button. Changes made by clicking an Update button are temporary and only submitted to the Ethernet Bridge or Gateway Pro, not the XML file. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 10 SureCross™ DX80 Web Configurator Login Instruction Manual Notes Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 11: Rf Devices Tab

    Configure Points information. To copy device parameters, fill in the From and To boxes with the appropriate device number (listed on the left side of the table) and click the Copy button. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 12 Flex 2DI, 2DO, 4AI FlexPower Node with two discrete in, two discrete out, and four analog in. This description also includes the Thermocouple and RTD nodes. M-GAGE M-GAGE™ Node Other Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 13: Configure Points

    To send all I/O data to the devices, use the Select Models screen by selecting the Send ALL checkbox and clicking the Update button. To send the individual I/O point changes, use the expanded Configure Points screen and the Send button. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 14 Max Bad Count: The max bad count refers to a user-established maximum count of consecutive failed polling attempts before the Gateway considers the RF link to have failed. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 15 Sampling I/O parameters. Setting the report rate to zero sets the system to report only when the values have changed, also called reporting on change of state. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 16: Expanded Configure Points

    “Other” Type #: Occasionally some newly designed and released devices will use I/O types not yet listed in the drop-down list for I/O Type. When this happens, Banner Engineering applications engineers will supply the “other” type number. Select Other from the I/O Type drop-down list and enter the I/O type number supplied by Banner Engineering into this field.
  • Page 17 If the units are 0-20 mA, the threshold, hysteresis, and delta values are entered as milliampere values. Selecting Temp C from the drop-down list changes the threshold, hysteresis, and delta units to degrees Celsius. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 18 Change button to send the changes to the DX83 Ethernet Bridge or the Gateway Pro and then click on the Send button to send these changes to the device. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 19: I/O Linking

    Change button to send the changes to the DX83 Ethernet Bridge or the Gateway Pro, then click on the Send button to send these changes to the device. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 20: Scaling

    Update button: Submits changed data values to the Ethernet Bridge. Changes made by clicking an Update button are temporary until the changes are saved permanently in the configuration file. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 21: Remote I/O

    Refresh button: Displays the most current device information. Reset button: Resets any error conditions displayed. Until the error message is reset, the device will not start any additional operations. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 22: Dx80 Is Modbus/Tcp Client/Server (Default)

    Modbus master device and only communicates with the device configured as Slave ID 1: the Gateway. Node 1 Registers 17-32 DX80 Gateway Registers 1-16 DX83 Ethernet Bridge Slave ID 1 Node 2 Registers 33-48 Node 3 Registers 49-64 Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 23: Dx80 Gateway Is Modbus Rtu Master

    Remote Type: Select a type from the following drop-down list: none, coil (output), discrete input, input register, or holding register. DX80 device registers are all holding registers. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 24 Holding Register 4xxxx - SureCross slave devices, read/write, 16 bit Banner Engineering’s SureCross™ slave devices use only input registers and holding registers. When using slave devices from other manufacturers, please refer to the manufacturer’s documentation to determine what I/O types they use.
  • Page 25: Dx80 Is Modbus Rtu Slave

    Pro as a slave device. This selection stops the communication between the Ethernet interface and the DX80 Gateway. DX80 is Modbus RTU Slave mode was created for special configurations of Gateway Pro or Ethernet Bridge devices. Contact Banner Wireless Support for more information. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 26 SureCross™ DX80 Web Configurator RF Devices Tab Instruction Manual Notes Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 27: Network Tab

    Prev and Next buttons: Scrolls through the pages of registers for the selected slave (RTU unit). Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 28: Rtu Error Codes

    When A is code 2, indicating an exception code was returned, B indicates the exception as follows: 1: Illegal function code 2: Illegal data address (the requested register does not exist in the device) 3: Illegal data value Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 29: Tcp Error Codes

    Update to reset the counts. Click Update to view the most 2: Illegal data address (the requested register does not recent data values. exist in the device) 3: Illegal data value Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 30: Modbus Rtu Setup Submenu

    Remote Type: Select a type from the following drop-down list: none, coil (output), discrete input, input register, or holding register. Banner Engineering’s SureCross™ slave devices use only input registers and holding registers. When using slave devices from other manufacturers, please refer to the manufacturer’s documentation to determine what I/O types they use.
  • Page 31 Prev and Next buttons: Scrolls through the maps/rules. the list until it is deleted. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 32: Expanded Rtu Read Map

    None as the register type. Prev and Next buttons: Scrolls through the maps/rules. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 33: Rtu Write Map

    Holding Register 4xxxx - SureCross slave devices, read/write, 16 bit Banner Engineering’s SureCross™ slave devices use only input registers and holding registers. When using slave devices from other manufacturers, please refer to the manufacturer’s documentation to determine what I/O types are used.
  • Page 34: Expanded Rtu Write Map

    RTU Write Map primary view in addition to a few more parameters. Please refer to the Expanded RTU Read Map section for more information about these parameters. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 35: Modbus Tcp Setup Submenu

    “big endian,” therefore Modbus defaults to having the high order register first for double and float formats. If the low order register comes first on the accessed device, check the Swapped box. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 36: Client Read Map

    Holding Register 4xxxx - SureCross slave devices, read/write, 16 bit Banner Engineering’s SureCross™ slave devices use only input registers and holding registers. When using devices from other manufacturers, please refer to the manufacturer’s documentation to determine what I/O types are used.
  • Page 37: Expanded Client Read Map

    Client Read Map primary view, in addition to a few more parameters. Please refer to the RTU Read Map expanded view section for more information about these parameters. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 38: Client Write Map

    Holding Register 4xxxx - SureCross slave devices, read/write, 16 bit Banner Engineering’s SureCross™ slave devices use only input registers and holding registers. When using slave devices from other manufacturers, please refer to the manufacturer’s documentation to determine what I/O types are used.
  • Page 39: Expanded Client Write Map

    Client Write Map primary view, in addition to a few more parameters. Please refer to the RTU Read Map expanded view section for more information about these parameters. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 40: Server Map

    Result copied to Mapped Register 005A 0FF0 05A0 005A F0F0 00A0 005A 00FF 005A 005A FF00 5A00 1234 0F0F 0204 A second example is given below, using the Server Map screen. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 41 None as the register type. Prev and Next buttons: Scrolls through the maps/rules. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 42 SureCross™ DX80 Web Configurator Network Tab Instruction Manual Notes Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 43: System Tab

    Next button will display registers 17 through 32 and the device number changes to show #2 Node. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro and/or updates the screen display. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 44: Thresholds

    Check the Reset box and click the Update button to reset the trend data, clear the graph, and reset the minimum and maximum tracking. Prev and Next buttons: Displays the page of rules. Update button: Updates the screen display. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 45: Action Rules Submenu

    Register to log the ON time to Comparison fixed value TRUE fixed value Comparison local register Local register Hysteresis FALSE fixed value Hysteresis ON time Local register Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 46 Prev and Next buttons: Displays the next rule or next page of rules. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 47: Trending

    Insert button: Inserts a new trend number in front of the trend number listed in the Showing box. Prev and Next buttons: Displays the next rule. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 48: Cascade

    Select and or thru to select two registers or multiple registers in a range. Average, sum, and logic operations are valid for ranges of multiple registers. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 49: Constants

    Insert button: Inserts a new rule number in front of the rule listed in the Showing box. Prev and Next buttons: Displays the next rule. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 50: Setup Submenu

    Find the option among the browser settings to delete cached files from the PC and re-upload the file. In some cases, exit and restart the browser. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 51: Network

    When using a Dynamic DNS service to keep track of this device on the Internet, select the service type, enter the host name the service uses for this device, and enter the user name and password Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 52 The host name does exist, but not under the user name given abuse The host name given is blocked for abuse. Error messages returned by the dynamic DNS service(s) that require the attention of Banner Engineering include: Error Code Meaning...
  • Page 53: User

    The current user’s name is displayed. To change the password, enter the old password, the new password, and confirm the new password by entering it again. Click the Accept button to submit the change. This change takes effect immediately. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 54 If the IP filter is a non-zero valid IP address, the user may only log in from that IP address. After making changes to this screen, select the Confirm Change checkbox, then click the Change button to submit the changes. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 55: Time And Date

    Time zone is offset from GMT, 0 through 24, moving west around the world. As an example, Chicago is at latitude +41.83, longitude -87.75, time zone +6. Time zones for the Banner devices are set up with west of GMT as positive numbers.
  • Page 56 SureCross™ DX80 Web Configurator System Tab Instruction Manual Notes Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 57: Advanced Tab

    Once a holiday is added to the schedule, the scheduled event that normally happens on the selected days will not occur if one of the selected days falls on one of the excluded holidays. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 58 Other Commands Prev and Next buttons: Displays the next schedule. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 59: On Demand

    Prev and Next buttons: Displays the next page of On Demand events. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 60: Holidays

    > Config File page and click the Save button. Changes made by clicking an Update button are temporary until the changes are saved permanently into the configuration file. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 61: Data Logger Submenu

    Status hyperlink: Displays a complete list of error conditions. For a list of error codes, refer to Appendix B, Error Codes. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 62 Reset Errors button: Resets status error messages or conditions. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro and refreshes the screen display. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 63: Data Points

    Prev and Next buttons: Scrolls through the registers of the device listed to the left of the Showing box. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 64: Events Logged

    Prev and Next buttons: Scrolls through the pages of event and log files. Refresh button: Refreshes the data displayed on the screen to include any new files created since the page was first opened. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 65: E-Mail Alerts Submenu

    Next button to enter another e-mail address and select another type of message notification. Each name should be in the form of myname@mycompany.com. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 66 Prev and Next buttons: Use the Prev and Next buttons to scroll through the three groups of e-mail recipients. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 67: Events

    Prev and Next buttons: Use the Prev and Next buttons to scroll through the list of events if the events list requires more than one page. Update button: Sends new data or settings to the Ethernet Bridge or Gateway Pro. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 68: E-Mail Server

    If the POP3 server is known by domain name, use the name instead and set the IP address to zero. The system name and location are included in the default e-mail message to identify the e-mail’s origin. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 69: Script Basic Submenu

    Start: Runs the selected program in the background. If the same file is also selected to auto run at startup, clicking the Start button will run two copies of the program. Do not run two copies of the same program. Selected and currently active file Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 70: View/Edit

    4K as a single text buffer. For larger programs, edit the source code on a PC and upload the program in the Program File page. Selected file Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 71: Virtual Terminal

    Use the Clear button to discard old output. Note that the Enter and Refresh buttons both act as submit buttons. Input present in the input box is submitted when any button is clicked. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 72 SureCross™ DX80 Web Configurator Advanced Tab Instruction Manual Notes Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 73: Basic Configuration

    Save these settings by going to System > Setup > Config File and clicking the Save or Save As button. This ensures that the configuration file contains the most recent information stored on the SureCross devices. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 74: I/O Configuration

    For detailed definitions of all parameters on this and the expanded view screen, please refer to the RF Device Tab section. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 75: I/O Linking

    1. Similarly, device 1’s inputs 1, 2, 5, and 6 are mapped to device 0’s outputs 9, 10, 13, and 14. Banner Engineering does not recommend linking multiple inputs to a single output on any SureCross device. The result will not be “Logic OR” of the multiple inputs; rather, the output will respond to any input state changes as they occur.
  • Page 76: Link Timeout

    Click the Send Flags button to submit changes to the flags to the devices. Use the Prev and Next buttons to scroll to the next SureCross™ device. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 77: System Network Settings

    DNS server IP address. The DNS server addresses are supplied by an Internet Service Provider (ISP) or network administrator. 3. Select a dynamic DNS service and enter in the device’s host name, the DDNS user name, and password. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 78: Advanced Configuration

    Also go to the System > Setup > Config File page and click the Save or Save As buttons to save the configuration changes. If you leave a page after making changes and have not submitted those changes to the device, the changes are lost. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 79: Data And Event Logging

    Refresh button to show the latest entry or entries recorded into the Log file. To delete files, select the checkbox in front of the unnecessary files and click the Delete button. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 80 In the sample shown, 16 register entries logged every second to a maximum file size of 1 Kb fills up the file in less than a minute. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 81: Scheduling

    Sundays, and any holiday in the list to the right occurring on the selected days. An On Demand event is set up similarly, except that it occurs only once on a specified date. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164...
  • Page 82: Trending Data

    20 before being written to registers. To convert back to a temperature, enter 0.05 as the scale for that register. The value written to the floating point register for that I/O register is the temperature. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 83: Floating Point Registers

    The floating point registers associated with each I/O point are assigned based on the following equation: 1000 + I/O# • 2 - 1. For example, I/O Point Floating Point Register 1001, 1002 1003, 1004 1005, 1006 1007, 1008 1009, 1010 Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 84 SureCross™ DX80 Web Configurator Examples Instruction Manual Notes Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 85: Appendix A - Troubleshooting

    Wait 30 seconds Remove the jumper Cycle power to the device Using the configuration web page, verify the parameters have returned to the factory defaults listed in the table. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 86: Troubleshooting

    SureCross™ DX80 Web Configurator Troubleshooting Instruction Manual Notes Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 87: Appendix B - Reference Information

    Unknown x/y A status x with code y has not been enumerated for the web page. Please contact Banner technical support and provide the values of x and y. File System Error Codes The file system errors are listed in the following table.
  • Page 88 NAFS_BUFFER_POOL_ALREADY_INSTALLED NAFS_REMOVE_VOLUME_FAILED NAFS_INVALID_PATH_NAME NAFS_SERVICES_CB_NOT_ALLOCATED NAFS_MEDIA_TYPE_INTF_MISMATCH NAFS_VOLUME_NOT_INITIALIZED NAFS_BUFFER_POOL_EMPTY NAFS_THREAD_DELETE_FAILED NAFS_INVALID_FILE_NAME_LENGTH NAFS_THREAD_TERMINATE_FAILED NAFS_INVALID_FILE_TYPE NAFS_SEMAPHORE_DELETE_FAILED NAFS_INVALID_FILE_ACCESS_TYPE NAFS_FLASH_VOLUME_SECTORS_MISMATCH NAFS_INVALID_FILE_NAME NAFS_SERVICES_CB_NOT_INITIALIZED NAFS_IO_REQUEST_CB_BUSY NAFS_INODE_NUMBER_MISMATCH NAFS_FILE_CB_BUSY NAFS_SHUTDOWN_MODE NAFS_DIR_PATH_CB_BUSY NAFS_THREAD_GET_INFO_FAILED NAFS_IO_REQUEST_CB_NOT_INITIALIZED NAFS_SEND_IO_REQUEST_FAILED NAFS_MSG_QUEUE_FULL NAFS_INVALID_ROOT_DIR_INODE NAFS_INVALID_DIR_NAME_LENGTH Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 89: E-Mail Error Codes

    (-15) indicates the data log file that the DX80 was attempting to attach eSendMail_BodyFull to an e-mail could not be accessed. eSendMail_NoDNSaddress Negative Description Error Codes NAMAILC_OK NAMAILC_MISSADDRESS NAMAILC_INVALIDBODY NAMAILC_NOSERVER NAMAILC_NOMAILBOX NAMAILC_TCPERROR NAMAILC_CANCELLED NAMAILC_SYNTAXERROR NAMAILC_MAILBOXBUSY NAMAILC_GENERALERROR NAMAILC_BUFFERFULL NAMAILC_FILESYSTEMERROR NAMAILC_INVALIDFILE Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 90: Floating Point Registers

    Connection refused Connection aborted Network is unreachable Connection timed out Host is unreachable Connection in progress (connect unsuccessful and still trying) Could not get host IP by name Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 91: Rtu And Tcp Error Codes

    Could not reach local DNS to look up remote host 2006 HTTP client aborted a web session < 200 Unexpected network errors. Contact Banner Engineering if these errors occur. Error messages that may be returned by the dynamic DNS service(s), noted as last reply, include: Error Code Meaning...
  • Page 92 SureCross™ DX80 Web Configurator Error Codes Instruction Manual Notes Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 93: Index

    Events 67 Modbus Devices 35 Events, Setting Up 45 User Setup 53 Event Scheduling 81 Root Login 54 Events Logged 64 Network 51 Node Link Failure 14 Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 94 For the most accurate explanations of a specific parameter, please refer to the manual section pertaining to the specific screen or Web page in question. Some functions may not retain the same definition across multiple screens. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 95 Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 P/N 134421...
  • Page 96 This warranty is in lieu of any other warranty either expressed or implied. All specifications published in this document are subject to change. Banner reserves the right to modify the specifications of products, prior to their order, without notice. Banner Engineering reserves the right to update or change documentation at any time. For the most recent version of any documentation, please refer to our website: www.bannerengineering.com.

This manual is also suitable for:

Surecross dx83 ethernet bridge

Table of Contents